Development and Validation of RP-HPLC Method for Quantification of Clindamycin Phosphate and Tretinoin Drug-Loaded Microgel

The current study aimed to develop and validate a reverse-phase high-performance liquid chromatographic (RP-HPLC) method that is quick, easy, and sensitive for the simultaneous measurement of tretinoin and clindamycin phosphate in lipid-based semisolid pharmaceutical formulations, particularly microgel. Due to the difficulties involved in co-analysing a hydrophilic and a lipophilic drug inside the same matrix, a strong analytical technique was necessary for precise and repeatable quantification. Chromatographic separation was accomplished using a Phenomenex C-18 column (150 mm × 4.6 mm, 5 µm) and an isocratic mobile phase consisting of 0.01 N phosphate buffer and acetonitrile (20:80, v/v) at a flow rate of 1.0 mL/min. Clindamycin phosphate and tretinoin were detected at wavelengths of 210 and 353 nm, respectively. Standard calibration curves were created across a concentration range of 2–50 µg/mL for both analytes. The limits of detection (LOD) and quantification (LOQ) for clindamycin phosphate and tretinoin were 6.78 µg/mL and 20.56 µg/mL, respectively, and 0.14 µg/mL and 0.42 µg/mL, demonstrating the method's good linearity (R² = 0.99). With %RSD values constantly below 2%, recovery trials at three concentration levels (70%, 100%, and 120%) showed mean accuracy ranging from 98.18% to 102.93% for clindamycin phosphate and 116.80% to 123.36% for tretinoin. These results validated the accuracy, precision, and repeatability of the approach. This method effectively verified the entrapment efficiency of the drug-loaded microgel, meeting ICH requirements, and is suitable for regular quality control of combination formulations containing tretinoin and clindamycin.

Authors

Institutions

Publication Details

Journal
Atlantic Journal of Life Sciences
Published
2025-05-31
DOI
https://doi.org/10.71005/a0ht4r94
Citations
2
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
1.51
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of RP-HPLC Method for Quantification of Clindamycin Phosphate and Tretinoin Drug-Loaded Microgel

Muhammad Ibrahim, Hafiz Muhammad Bilal Khalid, Maida Minahil Mushtaq, Yasir Mehmood et al.
2 citations
Atlantic Journal of Life Sciences
Analytical Chemistry and Chromatography
1.51
article

Development and Validation of RP-HPLC Method for Quantification of Clindamycin Phosphate and Tretinoin Drug-Loaded Microgel

Muhammad Ibrahim, Hafiz Muhammad Bilal Khalid, Maida Minahil Mushtaq, Yasir Mehmood, Muhammad Torequl Islam
article en
2 citations

Abstract

The current study aimed to develop and validate a reverse-phase high-performance liquid chromatographic (RP-HPLC) method that is quick, easy, and sensitive for the simultaneous measurement of tretinoin and clindamycin phosphate in lipid-based semisolid pharmaceutical formulations, particularly microgel. Due to the difficulties involved in co-analysing a hydrophilic and a lipophilic drug inside the same matrix, a strong analytical technique was necessary for precise and repeatable quantification. Chromatographic separation was accomplished using a Phenomenex C-18 column (150 mm × 4.6 mm, 5 µm) and an isocratic mobile phase consisting of 0.01 N phosphate buffer and acetonitrile (20:80, v/v) at a flow rate of 1.0 mL/min. Clindamycin phosphate and tretinoin were detected at wavelengths of 210 and 353 nm, respectively. Standard calibration curves were created across a concentration range of 2–50 µg/mL for both analytes. The limits of detection (LOD) and quantification (LOQ) for clindamycin phosphate and tretinoin were 6.78 µg/mL and 20.56 µg/mL, respectively, and 0.14 µg/mL and 0.42 µg/mL, demonstrating the method's good linearity (R² = 0.99). With %RSD values constantly below 2%, recovery trials at three concentration levels (70%, 100%, and 120%) showed mean accuracy ranging from 98.18% to 102.93% for clindamycin phosphate and 116.80% to 123.36% for tretinoin. These results validated the accuracy, precision, and repeatability of the approach. This method effectively verified the entrapment efficiency of the drug-loaded microgel, meeting ICH requirements, and is suitable for regular quality control of combination formulations containing tretinoin and clindamycin.

Atlantic Journal of Life SciencesVol. 2025(1)
University of Lahore (PK), Nuclear Institute for Agriculture and Biology (PK), Government College University, Faisalabad (PK)
Openalex Percentile: Top 18%
Analytical Chemistry and Chromatography
1.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.