New 3D segmentation algorithm for modeling of kidney in positron emission tomography images

Abstract Background $$^{15}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mmultiscripts> <mml:mrow/> <mml:mrow/> <mml:mn>15</mml:mn> </mml:mmultiscripts> </mml:math> O-water positron emission tomography (PET) imaging enables noninvasive quantification of renal blood flow. While there are several existing methods automatically locating the volume of interest (VOI) for a kidney, separate cortex and medulla VOIs are needed for PET modeling due their functional differences. To assist in this, we introduce a new three-dimensional segmentation algorithm for kidney. Materials and methods Our algorithm chooses an initial kidney VOI, finds its longitudinal axis and the direction of the non-convex part, and then creates cortex and medulla VOIs and removes the renal vessel area from them. We evaluated the algorithm by using it to define cortex and medulla VOIs of left and right kidneys in dynamic total-body $$^{15}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mmultiscripts> <mml:mrow/> <mml:mrow/> <mml:mn>15</mml:mn> </mml:mmultiscripts> </mml:math> O-water PET images of 35 human patients. For all the 70 kidneys, we plotted the cross-section of the VOIs from three different anatomic directions and asked two expert physicians to assess their quality. Additionally, we computed cortical and medullary renal blood flow estimates by fitting a compartment model to the mean time-activity curves of our VOIs. Results According to the evaluation by the physicians, the cortex and medulla VOIs were mostly correct in all three directions for 78.6% of the total 70 kidneys and correct in at least one direction for 94.3% of the kidneys. The segmentation inaccuracies were typically caused by the algorithm placing cortex VOI partially outside of the kidney or in the medulla. However, regardless of these inaccuracies, all the VOIs were accurate enough to be used for compartment modeling. The resulting cortical and medullary blood flow were very close to the values reported in earlier studies with similar patient populations. Conclusion Our proposed algorithm can be used to create an automatic pipeline for accurate quantification of cortical and medullary tracer perfusion after a PET scan.

Authors

Institutions

Publication Details

Journal
Network Modeling Analysis in Health Informatics and Bioinformatics
Published
2025-05-31
DOI
https://doi.org/10.1007/s13721-025-00534-0
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New 3D segmentation algorithm for modeling of kidney in positron emission tomography images

Aino Latva‐Rasku, Oona Rainio, Jussi Hirvonen, Riku Klén et al.
1 links
Network Modeling Analysis in Health Informatics and Bioinformatics
Medical Image Segmentation Techniques
article

New 3D segmentation algorithm for modeling of kidney in positron emission tomography images

Aino Latva‐Rasku, Oona Rainio, Jussi Hirvonen, Riku Klén, Juhani Knuuti
article en

Abstract

Abstract Background $$^{15}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mmultiscripts> <mml:mrow/> <mml:mrow/> <mml:mn>15</mml:mn> </mml:mmultiscripts> </mml:math> O-water positron emission tomography (PET) imaging enables noninvasive quantification of renal blood flow. While there are several existing methods automatically locating the volume of interest (VOI) for a kidney, separate cortex and medulla VOIs are needed for PET modeling due their functional differences. To assist in this, we introduce a new three-dimensional segmentation algorithm for kidney. Materials and methods Our algorithm chooses an initial kidney VOI, finds its longitudinal axis and the direction of the non-convex part, and then creates cortex and medulla VOIs and removes the renal vessel area from them. We evaluated the algorithm by using it to define cortex and medulla VOIs of left and right kidneys in dynamic total-body $$^{15}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mmultiscripts> <mml:mrow/> <mml:mrow/> <mml:mn>15</mml:mn> </mml:mmultiscripts> </mml:math> O-water PET images of 35 human patients. For all the 70 kidneys, we plotted the cross-section of the VOIs from three different anatomic directions and asked two expert physicians to assess their quality. Additionally, we computed cortical and medullary renal blood flow estimates by fitting a compartment model to the mean time-activity curves of our VOIs. Results According to the evaluation by the physicians, the cortex and medulla VOIs were mostly correct in all three directions for 78.6% of the total 70 kidneys and correct in at least one direction for 94.3% of the kidneys. The segmentation inaccuracies were typically caused by the algorithm placing cortex VOI partially outside of the kidney or in the medulla. However, regardless of these inaccuracies, all the VOIs were accurate enough to be used for compartment modeling. The resulting cortical and medullary blood flow were very close to the values reported in earlier studies with similar patient populations. Conclusion Our proposed algorithm can be used to create an automatic pipeline for accurate quantification of cortical and medullary tracer perfusion after a PET scan.

Network Modeling Analysis in Health Informatics and BioinformaticsVol. 14(1)
University of Turku (FI), Turku University Hospital (FI), Turku PET Centre (FI)
Suomen Lääketieteen Säätiö, Turun Yliopisto, Otto A. Malm Lahjoitusrahasto
Openalex Percentile: Top 90%
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.