Electrical spectroscopic analysis of a sheep’s kidney at low-frequencies

Bioelectrical Impedance Analysis (BIA) and Bioimpedance Spectroscopy (BIS) are valuable tools for characterizing tissue structure and composition. This study investigates the low-frequency electrical properties (< 10 Hz) of sheep kidney tissue using a custom-designed impedance spectroscopy system. Sheep kidneys are selected due to their anatomical and physiological similarity to human kidneys, making them a suitable ex vivo model for biomedical studies. Four kidney samples were analyzed to assess key electrical parameters, including admittance, conductivity, relative permittivity, and power factor. The results revealed a distinct peak in the imaginary part of conductivity and the admittance phase at frequencies below 30 mHz, indicating dominant capacitive behavior and energy storage mechanisms. These findings offer insights into tissue-specific dielectric responses and may support future applications in non-invasive diagnostics and therapeutic monitoring.

Authors

Institutions

Publication Details

Journal
Discover Applied Sciences
Published
2025-05-31
DOI
https://doi.org/10.1007/s42452-025-07209-5
Citations
1
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrical spectroscopic analysis of a sheep’s kidney at low-frequencies

Faezeh Azimi Pirsoltan, Mohammad Reza Karafi
1 citations
Discover Applied Sciences
Electrical and Bioimpedance Tomography
0.73
article

Electrical spectroscopic analysis of a sheep’s kidney at low-frequencies

Faezeh Azimi Pirsoltan, Mohammad Reza Karafi
article en
1 citations

Abstract

Bioelectrical Impedance Analysis (BIA) and Bioimpedance Spectroscopy (BIS) are valuable tools for characterizing tissue structure and composition. This study investigates the low-frequency electrical properties (< 10 Hz) of sheep kidney tissue using a custom-designed impedance spectroscopy system. Sheep kidneys are selected due to their anatomical and physiological similarity to human kidneys, making them a suitable ex vivo model for biomedical studies. Four kidney samples were analyzed to assess key electrical parameters, including admittance, conductivity, relative permittivity, and power factor. The results revealed a distinct peak in the imaginary part of conductivity and the admittance phase at frequencies below 30 mHz, indicating dominant capacitive behavior and energy storage mechanisms. These findings offer insights into tissue-specific dielectric responses and may support future applications in non-invasive diagnostics and therapeutic monitoring.

Discover Applied SciencesVol. 7(6)
Tarbiat Modares University (IR)
Zero hunger
Openalex Percentile: Top 28%
Electrical and Bioimpedance Tomography
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.