<b>Method for Estimating Molten Volume of Current Collecting Materials at Contact Loss Point using <i>ϕ</i>-<i>θ</i> Theory</b>

In order to control electric wear of current collecting materials such as contact wires and contact strips in electric railways, it is necessary to understand the relationship between current and the molten volume at a contact loss point. In this paper, we propose a method for estimating the molten volume of the contact wire whose film resistance is taken into account, on the basis of the ϕ-θ theory. To verify the proposed method, we carried out wear tests under varying current conditions to measure the molten depth, molten radius, and molten volume. The wear test results showed that the experimental values of the molten volume of the contact wire are spread in the range where normalized potential at the contact boundary at which α was estimated to be 0.90 to 0.94.

Authors

Publication Details

Journal
Quarterly Report of RTRI
Published
2025-05-01
DOI
https://doi.org/10.2219/rtriqr.66.2_72
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Method for Estimating Molten Volume of Current Collecting Materials at Contact Loss Point using ϕ-θ Theory

Takuya OHARA, Koki NEMOTO, Chikara Yamashita
Quarterly Report of RTRI
Non-Destructive Testing Techniques
article

Method for Estimating Molten Volume of Current Collecting Materials at Contact Loss Point using ϕ-θ Theory

Takuya OHARA, Koki NEMOTO, Chikara Yamashita
article en

Abstract

In order to control electric wear of current collecting materials such as contact wires and contact strips in electric railways, it is necessary to understand the relationship between current and the molten volume at a contact loss point. In this paper, we propose a method for estimating the molten volume of the contact wire whose film resistance is taken into account, on the basis of the ϕ-θ theory. To verify the proposed method, we carried out wear tests under varying current conditions to measure the molten depth, molten radius, and molten volume. The wear test results showed that the experimental values of the molten volume of the contact wire are spread in the range where normalized potential at the contact boundary at which α was estimated to be 0.90 to 0.94.

Quarterly Report of RTRIVol. 66(2)
Openalex Percentile: Top 88%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.