Evaluation of HOP-MRA for post-coil embolization assessment of cerebral aneurysms: a comparative study with 3D-TOF MRA

Abstract Purpose Hybrid of opposite contrast magnetic resonance angiography (HOP-MRA) is a technique that enhances the visualization of slow-flow vessels by subtracting the low-signal component of flow-sensitive black blood (FSBB) imaging from the high-signal component of 3D time-of-flight (TOF) MRA. This study evaluates the utility of HOP-MRA in assessing residual lumen and parent artery structure following cerebral aneurysm coil embolization, focusing on its relevance in neurovascular imaging. Methods A comparative analysis was conducted using both in vitro phantom models and in vivo patient data. A phantom model containing a coiled aneurysm was assessed with HOP-MRA and 3D-TOF MRA to evaluate susceptibility artifacts. Additionally, 12 patients with 13 coiled aneurysms underwent both imaging modalities. Aneurysm remnant and parent artery visualization were graded using a three-grade scale, and interobserver agreement was analyzed. Results Phantom experiments revealed increased susceptibility artifacts with HOP-MRA, particularly in the parent artery region. However, in vivo imaging demonstrated no significant difference in parent artery and aneurysm remnant visualization between HOP-MRA and 3D-TOF MRA (interobserver agreement: 96%). HOP-MRA provided more anatomically accurate depictions in select cases compared with digital subtraction angiography, particularly in small residual aneurysm remnants. Conclusion Despite susceptibility artifacts observed in vitro, HOP-MRA demonstrated comparable performance to 3D-TOF MRA in assessing post-embolization aneurysm remnants and adjacent vasculature. This suggests that HOP-MRA can be utilized as an alternative imaging technique, particularly in cases where slow-flow remnants are suspected, when appropriate parameters are applied.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Radiology and Nuclear Medicine
Published
2025-05-30
DOI
https://doi.org/10.1186/s43055-025-01482-5
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of HOP-MRA for post-coil embolization assessment of cerebral aneurysms: a comparative study with 3D-TOF MRA

Kouichi Asahi
The Egyptian Journal of Radiology and Nuclear Medicine
Advanced MRI Techniques and Applications
article

Evaluation of HOP-MRA for post-coil embolization assessment of cerebral aneurysms: a comparative study with 3D-TOF MRA

Kouichi Asahi
article en

Abstract

Abstract Purpose Hybrid of opposite contrast magnetic resonance angiography (HOP-MRA) is a technique that enhances the visualization of slow-flow vessels by subtracting the low-signal component of flow-sensitive black blood (FSBB) imaging from the high-signal component of 3D time-of-flight (TOF) MRA. This study evaluates the utility of HOP-MRA in assessing residual lumen and parent artery structure following cerebral aneurysm coil embolization, focusing on its relevance in neurovascular imaging. Methods A comparative analysis was conducted using both in vitro phantom models and in vivo patient data. A phantom model containing a coiled aneurysm was assessed with HOP-MRA and 3D-TOF MRA to evaluate susceptibility artifacts. Additionally, 12 patients with 13 coiled aneurysms underwent both imaging modalities. Aneurysm remnant and parent artery visualization were graded using a three-grade scale, and interobserver agreement was analyzed. Results Phantom experiments revealed increased susceptibility artifacts with HOP-MRA, particularly in the parent artery region. However, in vivo imaging demonstrated no significant difference in parent artery and aneurysm remnant visualization between HOP-MRA and 3D-TOF MRA (interobserver agreement: 96%). HOP-MRA provided more anatomically accurate depictions in select cases compared with digital subtraction angiography, particularly in small residual aneurysm remnants. Conclusion Despite susceptibility artifacts observed in vitro, HOP-MRA demonstrated comparable performance to 3D-TOF MRA in assessing post-embolization aneurysm remnants and adjacent vasculature. This suggests that HOP-MRA can be utilized as an alternative imaging technique, particularly in cases where slow-flow remnants are suspected, when appropriate parameters are applied.

The Egyptian Journal of Radiology and Nuclear MedicineVol. 56(1)
Kajima Corporation (Japan) (JP), Dokkyo Medical University (JP), Saitama Medical University (JP)
Openalex Percentile: Top 81%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of HOP-MRA for post-coil embolization assessment of cerebral aneurysms: a comparative study with 3D-TOF MRA — Kouichi Asahi · The Egyptian Journal of Radiology and Nuclear Medicine (2025) | TGRS Research Map | TGRS