Skin Hydration Monitoring Using a Microwave Sensor: Design, Fabrication, and In Vivo Analysis

This article introduces a microwave sensor tailored for skin hydration monitoring. The design enables wireless operation by separating the sensing component from the reader, making it ideal for wearable devices like wristbands. The sensor consists of a semi-lumped LC resonator coupled to an inductive coil reader, where the capacitive part of the sensing tag is in contact with the skin. The variations in the skin hydration level alter the dielectric properties of the skin, which, in turn, modify the resonances of the LC resonator. Experimental in vivo measurements confirmed the sensor's ability to distinguish between four hydration conditions: wet skin, skin treated with moisturizer, untreated dry skin, and skin treated with Vaseline, by measuring the resonance frequencies of the sensor. Measurement of the input reflection coefficient (S11) using a vector network analyzer (VNA) revealed distinct reflection poles and zeros for each condition, demonstrating the sensor's effectiveness in detecting skin hydration levels. The sensing principle was analyzed using an equivalent circuit model and validated through measurements of a fabricated sensor prototype. The results confirm in vivo skin hydration monitoring by detecting frequency shifts in the reflection response within the 50-200 MHz range. The measurements and data analysis show less than 0.037% error in transmission zero (fz) together with less than 1.5% error in transmission pole (fp) while being used to detect skin hydration status on individual human subjects. The simplicity of the detection method, focusing on key frequency shifts, underscores the sensor's potential as a practical and cost-effective solution for non-invasive skin hydration monitoring. This advancement holds significant potential for skincare and biomedical applications, enabling detection without complex signal processing.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-05-30
DOI
https://doi.org/10.3390/s25113445
Citations
2
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Skin Hydration Monitoring Using a Microwave Sensor: Design, Fabrication, and In Vivo Analysis

Shabbir Chowdhury, Amir Ebrahimi, Francisco Javier Tovar-Lopez, Kamran Ghorbani
2 citations
Sensors
Microwave and Dielectric Measurement Techniques
1.46
article

Skin Hydration Monitoring Using a Microwave Sensor: Design, Fabrication, and In Vivo Analysis

Shabbir Chowdhury, Amir Ebrahimi, Francisco Javier Tovar-Lopez, Kamran Ghorbani
article en
2 citations

Abstract

This article introduces a microwave sensor tailored for skin hydration monitoring. The design enables wireless operation by separating the sensing component from the reader, making it ideal for wearable devices like wristbands. The sensor consists of a semi-lumped LC resonator coupled to an inductive coil reader, where the capacitive part of the sensing tag is in contact with the skin. The variations in the skin hydration level alter the dielectric properties of the skin, which, in turn, modify the resonances of the LC resonator. Experimental in vivo measurements confirmed the sensor's ability to distinguish between four hydration conditions: wet skin, skin treated with moisturizer, untreated dry skin, and skin treated with Vaseline, by measuring the resonance frequencies of the sensor. Measurement of the input reflection coefficient (S11) using a vector network analyzer (VNA) revealed distinct reflection poles and zeros for each condition, demonstrating the sensor's effectiveness in detecting skin hydration levels. The sensing principle was analyzed using an equivalent circuit model and validated through measurements of a fabricated sensor prototype. The results confirm in vivo skin hydration monitoring by detecting frequency shifts in the reflection response within the 50-200 MHz range. The measurements and data analysis show less than 0.037% error in transmission zero (fz) together with less than 1.5% error in transmission pole (fp) while being used to detect skin hydration status on individual human subjects. The simplicity of the detection method, focusing on key frequency shifts, underscores the sensor's potential as a practical and cost-effective solution for non-invasive skin hydration monitoring. This advancement holds significant potential for skincare and biomedical applications, enabling detection without complex signal processing.

SensorsVol. 25(11)
RMIT University (AU)
RMIT University
Openalex Percentile: Top 17%
Microwave and Dielectric Measurement Techniques
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.