Is the Thin Bronchoscope the Right Compromise Between Ultrathin and Conventional Bronchoscopy for Peripheral Pulmonary Lesions (PPLs)? A Retrospective Study

<b>Background/Objectives:</b> Peripheral pulmonary lesions (PPLs) are the current challenge in bronchoscopy. Novel endoscopic approaches allow us to reach PPLs better than a few years ago. In patients with resectable non-small cell lung cancer (NSCLC), perioperative chemotherapy is associated with significantly greater event-free survival; this means that histological assessment before the resectable surgery of PPLs is becoming mandatory. Our objective was to evaluate the diagnostic yield (DY) of a thin bronchoscope (TB) for PPLs suspected for lung cancer that are not reachable with conventional bronchoscopy. <b>Methods:</b> A total of 176 patients with PPLs were evaluated from January 2022 to July 2023. Of the patients, 26 presented with not reachable PPLs with conventional bronchoscopy, and underwent the procedure again with a TB. When possible, R-EBUS was used. PPLs' dimensions were recorded via chest computed tomography (CT) scan. DY was evaluated. <b>Results:</b> Mean lesion size was 29 mm, and overall DY for TB was 65% (17/26). When the lesion was bigger than 20 mm, DY was 76.5% (13/17), whereas in lesions smaller than 20 mm, DY was 55% (5/9). When PPLs presented a bronchus sign in the CT scan, diagnostic performance of TB was significantly better (76.5% vs. 40%, p = 0.04) compared to PPLs without a bronchus sign, independent from PPL dimensions. R-EBUS did not change DY. <b>Conclusions:</b> TB easily allows us to reach and sample PPLs with a high DY if a bronchus sign is positive, independently from PPL dimensions. Further studies are needed to evaluate if more flexible and penetrating bronchial wall biopsy tools can augment DY for PPLs with TB.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-05-30
DOI
https://doi.org/10.3390/jcm14113855
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Is the Thin Bronchoscope the Right Compromise Between Ultrathin and Conventional Bronchoscopy for Peripheral Pulmonary Lesions (PPLs)? A Retrospective Study

Laura Mancino, G. Castelli, Gabriele Foltran, Filippo Lanfranchi et al.
Journal of Clinical Medicine
Lung Cancer Diagnosis and Treatment
article

Is the Thin Bronchoscope the Right Compromise Between Ultrathin and Conventional Bronchoscopy for Peripheral Pulmonary Lesions (PPLs)? A Retrospective Study

Laura Mancino, G. Castelli, Gabriele Foltran, Filippo Lanfranchi, Lucio Michieletto
article en

Abstract

<b>Background/Objectives:</b> Peripheral pulmonary lesions (PPLs) are the current challenge in bronchoscopy. Novel endoscopic approaches allow us to reach PPLs better than a few years ago. In patients with resectable non-small cell lung cancer (NSCLC), perioperative chemotherapy is associated with significantly greater event-free survival; this means that histological assessment before the resectable surgery of PPLs is becoming mandatory. Our objective was to evaluate the diagnostic yield (DY) of a thin bronchoscope (TB) for PPLs suspected for lung cancer that are not reachable with conventional bronchoscopy. <b>Methods:</b> A total of 176 patients with PPLs were evaluated from January 2022 to July 2023. Of the patients, 26 presented with not reachable PPLs with conventional bronchoscopy, and underwent the procedure again with a TB. When possible, R-EBUS was used. PPLs' dimensions were recorded via chest computed tomography (CT) scan. DY was evaluated. <b>Results:</b> Mean lesion size was 29 mm, and overall DY for TB was 65% (17/26). When the lesion was bigger than 20 mm, DY was 76.5% (13/17), whereas in lesions smaller than 20 mm, DY was 55% (5/9). When PPLs presented a bronchus sign in the CT scan, diagnostic performance of TB was significantly better (76.5% vs. 40%, p = 0.04) compared to PPLs without a bronchus sign, independent from PPL dimensions. R-EBUS did not change DY. <b>Conclusions:</b> TB easily allows us to reach and sample PPLs with a high DY if a bronchus sign is positive, independently from PPL dimensions. Further studies are needed to evaluate if more flexible and penetrating bronchial wall biopsy tools can augment DY for PPLs with TB.

Journal of Clinical MedicineVol. 14(11)
University of Padua (IT), Ospedale dell' Angelo (IT)
Openalex Percentile: Top 79%
Lung Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Is the Thin Bronchoscope the Right Compromise Between Ultrathin and Conventional Bronchoscopy for Peripheral Pulmonary Lesions (PPLs)? A Retrospective Study — Laura Mancino, G. Castelli, et al. · Journal of Clinical Medicine (2025) | TGRS Research Map | TGRS