Indoor Air Quality in Tehran’s Primary Schools: Seasonal Variations and Impact of External Pollution Sources on Pollutant Concentrations—A Comprehensive Analytical Study

The children’s sensitivity to high concentrations of pollutants in schools has led to increased attention to indoor air quality in recent years. Hence, the study was aimed at determining the concentration of air pollutants in primary school classrooms in Tehran during one academic year. For this purpose, the research team identified and evaluated primary schools in different regions of the Tehran megacity. Schools with similar characteristics were selected to sample CO 2 , PM 1 , PM 2.5 , and PM 10 pollutants in the indoor air of Tehran primary school classrooms. A total of 30 classrooms were sampled in five schools during the autumn, winter, and spring seasons of one academic year, spanning from September 2016 to May 2017. Data analysis was conducted using Python‐based tools, including Seaborn and Matplotlib, to generate visual insights. The results showed that the concentration of the pollutants studied differs significantly in winter compared to autumn and spring in the indoor air of the classrooms. The highest CO 2 , PM 1 , PM 2.5 , PM 10 , and PM Total concentrations were observed in the north, center, south, south, and south of Tehran, especially in the ground‐floor classrooms, respectively. The results of distance from green space, private space, and floors in winter emphasize an internal source of pollution; conversely, in spring and autumn, they show the influence of external sources on the concentration of pollutants inside the classrooms in various areas of Tehran. To summarize, the results of this study showed that the indoor air quality of primary school classrooms in Tehran requires careful investigation and urgent measures to reduce pollutants and improve environmental conditions to maintain the health and comfort of students and school board members.

Authors

Institutions

Publication Details

Journal
Indoor Air
Published
2025-01-01
DOI
https://doi.org/10.1155/ina/5518200
Citations
1
Primary Topic
Air Quality and Health Impacts
Type
article
Field-Weighted Citation Impact
1.20

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Indoor Air Quality in Tehran’s Primary Schools: Seasonal Variations and Impact of External Pollution Sources on Pollutant Concentrations—A Comprehensive Analytical Study

Maryam Borhani Jebeli, Rasul Nasiri, Sina Fazeli, Somayeh Soleimani-Alyar et al.
1 citations
Indoor Air
Air Quality and Health Impacts
1.20
article

Indoor Air Quality in Tehran’s Primary Schools: Seasonal Variations and Impact of External Pollution Sources on Pollutant Concentrations—A Comprehensive Analytical Study

Maryam Borhani Jebeli, Rasul Nasiri, Sina Fazeli, Somayeh Soleimani-Alyar, Rasoul Yarahmadi, Elham Maraghi, Golnaz Yarahmadi, Parvaneh Beyk Mohamadloo
article en
1 citations

Abstract

The children’s sensitivity to high concentrations of pollutants in schools has led to increased attention to indoor air quality in recent years. Hence, the study was aimed at determining the concentration of air pollutants in primary school classrooms in Tehran during one academic year. For this purpose, the research team identified and evaluated primary schools in different regions of the Tehran megacity. Schools with similar characteristics were selected to sample CO 2 , PM 1 , PM 2.5 , and PM 10 pollutants in the indoor air of Tehran primary school classrooms. A total of 30 classrooms were sampled in five schools during the autumn, winter, and spring seasons of one academic year, spanning from September 2016 to May 2017. Data analysis was conducted using Python‐based tools, including Seaborn and Matplotlib, to generate visual insights. The results showed that the concentration of the pollutants studied differs significantly in winter compared to autumn and spring in the indoor air of the classrooms. The highest CO 2 , PM 1 , PM 2.5 , PM 10 , and PM Total concentrations were observed in the north, center, south, south, and south of Tehran, especially in the ground‐floor classrooms, respectively. The results of distance from green space, private space, and floors in winter emphasize an internal source of pollution; conversely, in spring and autumn, they show the influence of external sources on the concentration of pollutants inside the classrooms in various areas of Tehran. To summarize, the results of this study showed that the indoor air quality of primary school classrooms in Tehran requires careful investigation and urgent measures to reduce pollutants and improve environmental conditions to maintain the health and comfort of students and school board members.

Indoor AirVol. 2025(1)
Ahvaz Jundishapur University of Medical Sciences (IR), Tarbiat Modares University (IR), Iran University of Medical Sciences (IR), Torbat Heydarieh University of Medical Sciences (IR), Knowledge Based Systems (United States) (US)
Iran University of Medical Sciences
Openalex Percentile: Top 22%
Air Quality and Health Impacts
1.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.