Establishing facility reference levels and comparing to international diagnostic reference levels in paediatric general X-ray

Diagnostic Reference Levels (DRLs) can be used to assess the radiation exposure for specific protocols and identify areas of potential optimisation. Despite paediatric general X-ray (GXR) being a relatively low dose modality, due to the high radiosensitivity of children, it is imperative that doses remain as low as reasonably achievable (ALARA). This study aims to compare our institute's Dose-Area-Product (DAP) to currently available local, national, and regional DRLs, as there are currently no Australian DRL values established for paediatric GXR. The DAPs for GXR protocols are recorded in a commercially available DMS software, MyXrayDose, which generates a report of the Facility Reference Levels (FRLs) for all GXR protocols. As MyXrayDose uses age categories, our FRLs were converted to weight-based FRLs using the 50th percentile values derived from the World Health Organisation and Centres for Disease Control Weight-for-age charts. These were compared to published DRLs from eleven different countries and regions of the world. Pelvis Anterior-Posterior (AP)/Posterior-Anterior (PA), Abdomen AP/PA, Thorax AP/PA and Thorax lateral protocols were compared to available national and regional DRLs. For example, from 1st July 2023-30th June 2024, 1008 Abdomen AP/PA X-rays were conducted in Room 1 with a fixed GXR unit. The FRL for 31.2-56.5 kg (10-15 years) patients in Room 1 (1093 mGy.cm<sup>2</sup>) was more than 2.3 times greater than the European DRL (475 mGy.cm<sup>2</sup>). The FRLs for patients with a mean weight of 6 kg and 14 kg were below the European DRL whilst 25 kg, 44 kg and 60 kg patients exceeded the European Abdomen AP/PA DRL. The establishment of DRLs helps institutes identify potential areas of optimisation. As some of our GXR protocols exceed the European DRLs, the next step at our institute is to complete a multi-disciplinary image quality assessment to identify if it is possible to optimise these protocols.

Authors

Institutions

Publication Details

Journal
Physical and Engineering Sciences in Medicine
Published
2025-05-30
DOI
https://doi.org/10.1007/s13246-025-01563-9
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishing facility reference levels and comparing to international diagnostic reference levels in paediatric general X-ray

Amanda Perdomo, Samuel Montgomery Lilli
Physical and Engineering Sciences in Medicine
Radiation Dose and Imaging
article

Establishing facility reference levels and comparing to international diagnostic reference levels in paediatric general X-ray

Amanda Perdomo, Samuel Montgomery Lilli
article en

Abstract

Diagnostic Reference Levels (DRLs) can be used to assess the radiation exposure for specific protocols and identify areas of potential optimisation. Despite paediatric general X-ray (GXR) being a relatively low dose modality, due to the high radiosensitivity of children, it is imperative that doses remain as low as reasonably achievable (ALARA). This study aims to compare our institute's Dose-Area-Product (DAP) to currently available local, national, and regional DRLs, as there are currently no Australian DRL values established for paediatric GXR. The DAPs for GXR protocols are recorded in a commercially available DMS software, MyXrayDose, which generates a report of the Facility Reference Levels (FRLs) for all GXR protocols. As MyXrayDose uses age categories, our FRLs were converted to weight-based FRLs using the 50th percentile values derived from the World Health Organisation and Centres for Disease Control Weight-for-age charts. These were compared to published DRLs from eleven different countries and regions of the world. Pelvis Anterior-Posterior (AP)/Posterior-Anterior (PA), Abdomen AP/PA, Thorax AP/PA and Thorax lateral protocols were compared to available national and regional DRLs. For example, from 1st July 2023-30th June 2024, 1008 Abdomen AP/PA X-rays were conducted in Room 1 with a fixed GXR unit. The FRL for 31.2-56.5 kg (10-15 years) patients in Room 1 (1093 mGy.cm<sup>2</sup>) was more than 2.3 times greater than the European DRL (475 mGy.cm<sup>2</sup>). The FRLs for patients with a mean weight of 6 kg and 14 kg were below the European DRL whilst 25 kg, 44 kg and 60 kg patients exceeded the European Abdomen AP/PA DRL. The establishment of DRLs helps institutes identify potential areas of optimisation. As some of our GXR protocols exceed the European DRLs, the next step at our institute is to complete a multi-disciplinary image quality assessment to identify if it is possible to optimise these protocols.

Physical and Engineering Sciences in MedicineVol. 48(3)
Royal Children's Hospital (AU)
Children's Hospital Foundation, Royal Children's Hospital Foundation
Partnerships for the goals
Openalex Percentile: Top 81%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.