Flexible wearable Fabry-Perot interferometer optic-fiber sensor with double parallel structure: realizing real-time breath monitoring enhanced by the means of Vernier effects

This paper presents and demonstrates what we believe to be a novel dual-parallel structure Fabry-Perot interferometer (FPI) flexible wearable fiber optic sensor with enhanced sensitivity through the Vernier effect for real-time human breath monitoring. The Fabry-Perot (FP) structure of the sensor is composed of a single-mode fiber fused to a capillary coated with an agar film at the end. The two FPIs are used as the reference element and the relative humidity (RH) sensing element, respectively. The influence of the capillary length difference on the RH response is experimentally investigated. The sensor has the best RH response in the range of 60%RH to 100%RH with an RH sensitivity of 2.93 nm/%RH. Based on the temperature experimental data, a sensitivity matrix can be constructed and solved to eliminate the influence of temperature on the sensor, so that it can be better applied to human breath monitoring. Through vibration and heating tests, it is verified that the sensor can eliminate the influence of external interference factors. In the applied research on breath monitoring of nine subjects, the sensor shows rapid response and recovery times of 0.47 s and 0.65 s, respectively. Combined with the random forest machine learning algorithm, this sensor is able to effectively differentiate the breathing patterns (normal and deep breathing) of different individuals (gender, body types). With high repeatability, reliability, and validity of the monitoring of breathing patterns, the proposed monitoring system provides a new way of thinking for the development of flexible and wearable breathing sensors.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-05-30
DOI
https://doi.org/10.1364/oe.564895
Citations
2
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexible wearable Fabry-Perot interferometer optic-fiber sensor with double parallel structure: realizing real-time breath monitoring enhanced by the means of Vernier effects

Jie Ma, Lidong Gong, Dandan Sun, Yingkuan Guo et al.
2 citations
Optics Express
Advanced Fiber Optic Sensors
1.46
article

Flexible wearable Fabry-Perot interferometer optic-fiber sensor with double parallel structure: realizing real-time breath monitoring enhanced by the means of Vernier effects

Jie Ma, Lidong Gong, Dandan Sun, Yingkuan Guo, Guoxin Shi, Wenwen Wang
article en
2 citations

Abstract

This paper presents and demonstrates what we believe to be a novel dual-parallel structure Fabry-Perot interferometer (FPI) flexible wearable fiber optic sensor with enhanced sensitivity through the Vernier effect for real-time human breath monitoring. The Fabry-Perot (FP) structure of the sensor is composed of a single-mode fiber fused to a capillary coated with an agar film at the end. The two FPIs are used as the reference element and the relative humidity (RH) sensing element, respectively. The influence of the capillary length difference on the RH response is experimentally investigated. The sensor has the best RH response in the range of 60%RH to 100%RH with an RH sensitivity of 2.93 nm/%RH. Based on the temperature experimental data, a sensitivity matrix can be constructed and solved to eliminate the influence of temperature on the sensor, so that it can be better applied to human breath monitoring. Through vibration and heating tests, it is verified that the sensor can eliminate the influence of external interference factors. In the applied research on breath monitoring of nine subjects, the sensor shows rapid response and recovery times of 0.47 s and 0.65 s, respectively. Combined with the random forest machine learning algorithm, this sensor is able to effectively differentiate the breathing patterns (normal and deep breathing) of different individuals (gender, body types). With high repeatability, reliability, and validity of the monitoring of breathing patterns, the proposed monitoring system provides a new way of thinking for the development of flexible and wearable breathing sensors.

Optics ExpressVol. 33(12)
Shanxi University of Traditional Chinese Medicine (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 17%
Advanced Fiber Optic Sensors
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.