Insertion thermometry experience at CERN

Abstract Insertion thermometry is desirable for low pressure gaseous cold helium environment due to the poor heat transfer coefficient between the fluid and the pipe wall, complicating the measurement on the insulation vacuum side. Insertion thermometry requires a capillary that, in the case of CERN equipment, has a wide variation of the overall length. Furthermore, the capillary is prone to inner pipe restrictions due to inappropriate bending or welding joints. The main advantage of insertion instrumentation is the exchangeability of damaged sensors; however, its installation can be extremely difficult in presence of restrictions and it is not trivial to ensure that the temperature sensor location reaches the end of the capillary inside the cold fluid’s vessel. This paper presents two approaches developed at CERN, they are based on either a sufficiently rigid stainless-steel wire with centering beads or a PCB carrier.

Authors

Institutions

Publication Details

Journal
IOP Conference Series Materials Science and Engineering
Published
2025-05-01
DOI
https://doi.org/10.1088/1757-899x/1327/1/012174
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Insertion thermometry experience at CERN

J. Casas, N. Vauthier, Matteo Bora, Florian Noly
IOP Conference Series Materials Science and Engineering
Particle Detector Development and Performance
article

Insertion thermometry experience at CERN

J. Casas, N. Vauthier, Matteo Bora, Florian Noly
article en

Abstract

Abstract Insertion thermometry is desirable for low pressure gaseous cold helium environment due to the poor heat transfer coefficient between the fluid and the pipe wall, complicating the measurement on the insulation vacuum side. Insertion thermometry requires a capillary that, in the case of CERN equipment, has a wide variation of the overall length. Furthermore, the capillary is prone to inner pipe restrictions due to inappropriate bending or welding joints. The main advantage of insertion instrumentation is the exchangeability of damaged sensors; however, its installation can be extremely difficult in presence of restrictions and it is not trivial to ensure that the temperature sensor location reaches the end of the capillary inside the cold fluid’s vessel. This paper presents two approaches developed at CERN, they are based on either a sufficiently rigid stainless-steel wire with centering beads or a PCB carrier.

IOP Conference Series Materials Science and EngineeringVol. 1327(1)
European Organization for Nuclear Research (CH)
Openalex Percentile: Top 74%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Insertion thermometry experience at CERN — J. Casas, N. Vauthier, et al. · IOP Conference Series Materials Science and Engineering (2025) | TGRS Research Map | TGRS