Experimental study of the thermo-hydraulic performance of 3-stream plate-fin heat exchanger

Abstract The performance of 3-stream plate-fin heat exchanger in a helium refrigerator plant having modified Claude cycle is crucial to achieve required refrigeration power. This 3-stream plate-fin heat exchanger has been designed using serrated fins of Al-alloy (Al3003) for 2 hot helium streams of flow rates ~13 g/s and ~17 g/s and cold helium stream of 30 g/s with cold end at ~15 K and hot end at ~27 K. The fabricated 3-stream heat exchanger has been tested down to 80 K in a simplified test bed before using it in the plant. In this test bed, for 3-stream heat exchanger, the temperature at cold end was ~90 K and at hot end, ~300 K. A simple test set-up has been made without a vacuum chamber and using insulation like nitrile rubber and MLI. In this test set up, thermo-hydraulic performances were measured successfully and found, by using ASPEN EDR software, to be quite nearer to designed value. The test set-up and results will be discussed in detail in this paper.

Authors

Institutions

Publication Details

Journal
IOP Conference Series Materials Science and Engineering
Published
2025-05-01
DOI
https://doi.org/10.1088/1757-899x/1327/1/012077
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study of the thermo-hydraulic performance of 3-stream plate-fin heat exchanger

P.S. Ghosh, A. K. Sahu, Navneet Kumar, Manoj Kumar Moharana et al.
IOP Conference Series Materials Science and Engineering
Heat Transfer and Optimization
article

Experimental study of the thermo-hydraulic performance of 3-stream plate-fin heat exchanger

P.S. Ghosh, A. K. Sahu, Navneet Kumar, Manoj Kumar Moharana, H. Kavad, Harshit K. Dave, O. Chandratre, Paritosh Chaudhuri, Viren Mishra, R. Bhatasana
article en

Abstract

Abstract The performance of 3-stream plate-fin heat exchanger in a helium refrigerator plant having modified Claude cycle is crucial to achieve required refrigeration power. This 3-stream plate-fin heat exchanger has been designed using serrated fins of Al-alloy (Al3003) for 2 hot helium streams of flow rates ~13 g/s and ~17 g/s and cold helium stream of 30 g/s with cold end at ~15 K and hot end at ~27 K. The fabricated 3-stream heat exchanger has been tested down to 80 K in a simplified test bed before using it in the plant. In this test bed, for 3-stream heat exchanger, the temperature at cold end was ~90 K and at hot end, ~300 K. A simple test set-up has been made without a vacuum chamber and using insulation like nitrile rubber and MLI. In this test set up, thermo-hydraulic performances were measured successfully and found, by using ASPEN EDR software, to be quite nearer to designed value. The test set-up and results will be discussed in detail in this paper.

IOP Conference Series Materials Science and EngineeringVol. 1327(1)
Indian Institute of Technology Kharagpur (IN), National Institute of Technology Rourkela (IN), Institute for Plasma Research (IN)
Openalex Percentile: Top 71%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental study of the thermo-hydraulic performance of 3-stream plate-fin heat exchanger — P.S. Ghosh, A. K. Sahu, et al. · IOP Conference Series Materials Science and Engineering (2025) | TGRS Research Map | TGRS