Experimental validation of a versatile test bench for thermal contraction measurements down to 1.8 K

Abstract The use of cryogenics plays a major role in the operation of modern high-energy accelerators and ensures, for instance, the superconducting state of beam-guiding and focusing magnets. A profound understanding of the thermo-mechanical behavior of the structures and components is therefore crucial, particularly for the strain-sensitive Nb 3 Sn-based superconducting coils. Inaccuracies in considering processes like thermal contraction can substantially impact the performance of the magnets. However, the scarcity of commercial thermal contraction measurement devices capable of examining these materials down to temperatures as low as 2 K has limited our knowledge of the thermal contraction within these complex systems. The Mechanical Measurement Laboratory at CERN has thus initiated the development of a customized dilatometric test bench in collaboration with the external company attoCUBE. The resulting setup features an optical displacement sensor based on Fiber-Optic Fabry-Pérot interferometry and, with its integration into a closed-cycle cryostat, this setup accommodates temperatures from room temperature down to a minimum of 1.8 K. Preliminary tests on known materials indicated the presence of a systematic error which was corrected by a calibration study using certified single-crystal silicon from the National Metrology Institute of Japan (NMIJ) as reference material. This study served simultaneously as the base for an uncertainty analysis to determine the remaining measurement uncertainty. Using the methods of the Guide to the expression of uncertainty in measurement (GUM), an uncertainty better than 0.01 × 10 −3 in ∆ L / L 0 over the entire temperature range was obtained. Given this level of uncertainty, this setup is well-balanced between accuracy and time efficiency, facilitating dynamic measurements across the entire low-temperature range within a 10-hour timeframe for a single measurement.

Authors

Institutions

Publication Details

Journal
IOP Conference Series Materials Science and Engineering
Published
2025-05-01
DOI
https://doi.org/10.1088/1757-899x/1327/1/012220
Primary Topic
Superconducting Materials and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental validation of a versatile test bench for thermal contraction measurements down to 1.8 K

Óscar Sacristán De Frutos, Michael Guinchard, Stefan Höll
IOP Conference Series Materials Science and Engineering
Superconducting Materials and Applications
article

Experimental validation of a versatile test bench for thermal contraction measurements down to 1.8 K

Óscar Sacristán De Frutos, Michael Guinchard, Stefan Höll
article en

Abstract

Abstract The use of cryogenics plays a major role in the operation of modern high-energy accelerators and ensures, for instance, the superconducting state of beam-guiding and focusing magnets. A profound understanding of the thermo-mechanical behavior of the structures and components is therefore crucial, particularly for the strain-sensitive Nb 3 Sn-based superconducting coils. Inaccuracies in considering processes like thermal contraction can substantially impact the performance of the magnets. However, the scarcity of commercial thermal contraction measurement devices capable of examining these materials down to temperatures as low as 2 K has limited our knowledge of the thermal contraction within these complex systems. The Mechanical Measurement Laboratory at CERN has thus initiated the development of a customized dilatometric test bench in collaboration with the external company attoCUBE. The resulting setup features an optical displacement sensor based on Fiber-Optic Fabry-Pérot interferometry and, with its integration into a closed-cycle cryostat, this setup accommodates temperatures from room temperature down to a minimum of 1.8 K. Preliminary tests on known materials indicated the presence of a systematic error which was corrected by a calibration study using certified single-crystal silicon from the National Metrology Institute of Japan (NMIJ) as reference material. This study served simultaneously as the base for an uncertainty analysis to determine the remaining measurement uncertainty. Using the methods of the Guide to the expression of uncertainty in measurement (GUM), an uncertainty better than 0.01 × 10 −3 in ∆ L / L 0 over the entire temperature range was obtained. Given this level of uncertainty, this setup is well-balanced between accuracy and time efficiency, facilitating dynamic measurements across the entire low-temperature range within a 10-hour timeframe for a single measurement.

IOP Conference Series Materials Science and EngineeringVol. 1327(1)
European Organization for Nuclear Research (CH)
Openalex Percentile: Top 73%
Superconducting Materials and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.