Design and commissioning of the cryogenic system for NNBI test facility

Abstract Cryopumps are used as the main pumps of cryo-vacuum systems in the Negative Neutral Beam Injectors (NNBI) test facility to pump gas to generate and maintain the vacuum gradient environment. To cool the cryopumps, a 1000 [email protected] K cryogenic system was built, which provides 4.5 K supercritical helium for cryopanels and 77 K liquid nitrogen for radiation baffles. The major cryogenic system components include helium recycle compressor, oil removal system (ORS), cold box, LHe Dewar, cryogenic distribution box, recovery compressor, helium purifier, gas bag, helium tanks, and LN2 tanks. Design, fabrication, and installation of most of the 1000 [email protected] K helium refrigerator was carried out at ASIPP. This paper presents an overview of the design and commissioning of the cryogenic system for NNBI test facility.

Authors

Institutions

Publication Details

Journal
IOP Conference Series Materials Science and Engineering
Published
2025-05-01
DOI
https://doi.org/10.1088/1757-899x/1327/1/012020
Primary Topic
Superconducting Materials and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and commissioning of the cryogenic system for NNBI test facility

Kai Yuan, Anyi Cheng, Qiyong Zhang, Zhigang Zhu et al.
IOP Conference Series Materials Science and Engineering
Superconducting Materials and Applications
article

Design and commissioning of the cryogenic system for NNBI test facility

Kai Yuan, Anyi Cheng, Qiyong Zhang, Zhigang Zhu, Yuanlai Xie, Zhihong Huang, Zhiwei Zhou, Keping Wu, Dengkui Ma, Qiaogang Song, G.H. Xia
article en

Abstract

Abstract Cryopumps are used as the main pumps of cryo-vacuum systems in the Negative Neutral Beam Injectors (NNBI) test facility to pump gas to generate and maintain the vacuum gradient environment. To cool the cryopumps, a 1000 [email protected] K cryogenic system was built, which provides 4.5 K supercritical helium for cryopanels and 77 K liquid nitrogen for radiation baffles. The major cryogenic system components include helium recycle compressor, oil removal system (ORS), cold box, LHe Dewar, cryogenic distribution box, recovery compressor, helium purifier, gas bag, helium tanks, and LN2 tanks. Design, fabrication, and installation of most of the 1000 [email protected] K helium refrigerator was carried out at ASIPP. This paper presents an overview of the design and commissioning of the cryogenic system for NNBI test facility.

IOP Conference Series Materials Science and EngineeringVol. 1327(1)
Chinese Academy of Sciences (CN), Hefei Institutes of Physical Science (CN), Institute of Plasma Physics (CN)
Openalex Percentile: Top 74%
Superconducting Materials and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and commissioning of the cryogenic system for NNBI test facility — Kai Yuan, Anyi Cheng, et al. · IOP Conference Series Materials Science and Engineering (2025) | TGRS Research Map | TGRS