The Optimization of a High Frequency Micro Pulse Tube Cryocooler

Abstract A micro coaxial pulse tube cryocooler has been developed to meet the requirements of high operating temperature infrared detection in space applications. To increase the efficiency of the cryocooler, the optimization experiments were designed. Driven by a double-piston opposed linear compressor with the mass less than 200 g, this cryocooler uses the inertance tubes and a reservoir as phase shifter and has the regenerator with a diameter of 10 mm. The effect of the operating frequencies and charging pressure on cooling performance were investigated through a series of experiments. This cryocooler can provide a cooling power of 0.61 W at 150 K with an input electric power of 10 W. This paper describes the optimizing processes and presents test data in detail.

Authors

Institutions

Publication Details

Journal
IOP Conference Series Materials Science and Engineering
Published
2025-05-01
DOI
https://doi.org/10.1088/1757-899x/1327/1/012052
Primary Topic
Advanced Thermodynamic Systems and Engines
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Optimization of a High Frequency Micro Pulse Tube Cryocooler

Houlei Chen, Geyang Li, Qingjun Tang, Yuhong Zhang et al.
IOP Conference Series Materials Science and Engineering
Advanced Thermodynamic Systems and Engines
article

The Optimization of a High Frequency Micro Pulse Tube Cryocooler

Houlei Chen, Geyang Li, Qingjun Tang, Yuhong Zhang, Ziyao Liu, Tianshi Feng, Jia Quan, Yuqiang Xun, Menglin Liang, Yuexue Ma
article en

Abstract

Abstract A micro coaxial pulse tube cryocooler has been developed to meet the requirements of high operating temperature infrared detection in space applications. To increase the efficiency of the cryocooler, the optimization experiments were designed. Driven by a double-piston opposed linear compressor with the mass less than 200 g, this cryocooler uses the inertance tubes and a reservoir as phase shifter and has the regenerator with a diameter of 10 mm. The effect of the operating frequencies and charging pressure on cooling performance were investigated through a series of experiments. This cryocooler can provide a cooling power of 0.61 W at 150 K with an input electric power of 10 W. This paper describes the optimizing processes and presents test data in detail.

IOP Conference Series Materials Science and EngineeringVol. 1327(1)
Technical Institute of Physics and Chemistry (CN), University of Chinese Academy of Sciences (CN)
Openalex Percentile: Top 73%
Advanced Thermodynamic Systems and Engines
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Optimization of a High Frequency Micro Pulse Tube Cryocooler — Houlei Chen, Geyang Li, et al. · IOP Conference Series Materials Science and Engineering (2025) | TGRS Research Map | TGRS