Experimental Study of High-efficiency Single-stage 30 K Coaxial Pulse Tube Cryocooler
Abstract The operating temperature of 30 K is crucial for long-wave infrared and very long-wave infrared detectors. To achieve cooling at 30 K, a two-stage pulse tube cryocooler (PTC) has been employed in most previous studies. However, these systems are complex in structure. Single-stage 30 K high-efEiciency PTC developments present signiEicant challenges but are essential for 30 K long-wave infrared detectors. We designed a single-stage coaxial PTC with a double inlet oriEice and conducted extensive optimization experiments on this cryocooler. With 200 W input power and a hot end temperature of 285 K, the PTC achieved a cooling capacity of 1.6 W/30 K, corresponding to a relative Carnot efEiciency of 6.8%.
Authors
- Ye Yuan (ORCID: https://orcid.org/0009-0005-9803-1167)
- Miguang Zhao (ORCID: https://orcid.org/0000-0002-4550-9105)
- Nailiang Wang
- Yanen Li
- GuoPeng Wang
- Min Tian Gao (ORCID: https://orcid.org/0000-0001-8063-3753)
- Bin Yang (ORCID: https://orcid.org/0000-0002-2087-4755)
- Geyang Li
Institutions
- Technical Institute of Physics and Chemistry (CN)
- University of Chinese Academy of Sciences (CN)
Publication Details
- Journal
- IOP Conference Series Materials Science and Engineering
- Published
- 2025-05-01
- DOI
- https://doi.org/10.1088/1757-899x/1327/1/012057
- Primary Topic
- Advanced Thermodynamic Systems and Engines
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Indiana Corn Marketing Council
- National Natural Science Foundation of China
- Chinese Academy of Sciences