Analysis and Tests of Hybrid Start-up Process of a Space Dilution Refrigeration Unit

Abstract Space dilution refrigerators for space applications have evolved over the past thirty years. The microgravity condition makes the helium isotope fluid flow and mix difficult in space. The surface tension of capillaries replaces gravity in the space dilution refrigerators, resulting in a different operating process compared with that of the ground systems. The start-up process of the space dilution refrigeration unit with a high pre-cooling temperature is carefully analyzed and tested. The dilution unit starts successfully and obtains 162 mK at a flow rate of 4 mL/min 3 He and 50 mL/min 4 He. The operating conditions and the phase interface location are carefully discussed for the performance and optimization based on the experimental results.

Authors

Institutions

Publication Details

Journal
IOP Conference Series Materials Science and Engineering
Published
2025-05-01
DOI
https://doi.org/10.1088/1757-899x/1327/1/012190
Primary Topic
Advanced Thermodynamic Systems and Engines
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and Tests of Hybrid Start-up Process of a Space Dilution Refrigeration Unit

Zijie Pan, Houlei Chen, Haowen Guo, J. H. Zou et al.
IOP Conference Series Materials Science and Engineering
Advanced Thermodynamic Systems and Engines
article

Analysis and Tests of Hybrid Start-up Process of a Space Dilution Refrigeration Unit

Zijie Pan, Houlei Chen, Haowen Guo, J. H. Zou, Maowen Zheng, Shubao Zhao, Jingtao Liang, Ziyao Liu, Lingjiao Wei
article en

Abstract

Abstract Space dilution refrigerators for space applications have evolved over the past thirty years. The microgravity condition makes the helium isotope fluid flow and mix difficult in space. The surface tension of capillaries replaces gravity in the space dilution refrigerators, resulting in a different operating process compared with that of the ground systems. The start-up process of the space dilution refrigeration unit with a high pre-cooling temperature is carefully analyzed and tested. The dilution unit starts successfully and obtains 162 mK at a flow rate of 4 mL/min 3 He and 50 mL/min 4 He. The operating conditions and the phase interface location are carefully discussed for the performance and optimization based on the experimental results.

IOP Conference Series Materials Science and EngineeringVol. 1327(1)
Technical Institute of Physics and Chemistry (CN), University of Chinese Academy of Sciences (CN)
Openalex Percentile: Top 74%
Advanced Thermodynamic Systems and Engines
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.