Experimental optimization of phase for a 20 K thermally-coupled two-stage high-frequency pulse tube cryocooler

Abstract With the rapid advancement of space technology, there is a continuous increase in demand for long-wave infrared detection devices, leading to higher requirements for two-stage pulse tube cryocoolers operating at liquid hydrogen temperatures. The performance of the cryocoolers is closely related to the inertance tube size. In order to improve a two-stage thermally-coupled pulse tube cryocooler’s performance in the liquid hydrogen temperature range, this study conducted phase optimization experiments, analyzed the effects of different inertance tube combinations on the cryocooler’s performance. The optimal operation frequency, power factor, no-load cooling temperature, cooling capacity and rCOP were compared for cryocoolers with different inertance tube combinations. After preliminary optimization, the cryocooler achieved 586 mW/20 K cooling power with a total electric power consumption of 185 W, resulting in a rCOP of 4.43%.

Authors

Institutions

Publication Details

Journal
IOP Conference Series Materials Science and Engineering
Published
2025-05-01
DOI
https://doi.org/10.1088/1757-899x/1327/1/012056
Primary Topic
Advanced Thermodynamic Systems and Engines
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental optimization of phase for a 20 K thermally-coupled two-stage high-frequency pulse tube cryocooler

Miguang Zhao, Yanen Li, Yuhong Zhang, Min Tian Gao et al.
IOP Conference Series Materials Science and Engineering
Advanced Thermodynamic Systems and Engines
article

Experimental optimization of phase for a 20 K thermally-coupled two-stage high-frequency pulse tube cryocooler

Miguang Zhao, Yanen Li, Yuhong Zhang, Min Tian Gao, Bin Yang, Yanjie Liu, Chenglong Liu, Jingtao Liang, Jia Quan, Yuqiang Xun
article en

Abstract

Abstract With the rapid advancement of space technology, there is a continuous increase in demand for long-wave infrared detection devices, leading to higher requirements for two-stage pulse tube cryocoolers operating at liquid hydrogen temperatures. The performance of the cryocoolers is closely related to the inertance tube size. In order to improve a two-stage thermally-coupled pulse tube cryocooler’s performance in the liquid hydrogen temperature range, this study conducted phase optimization experiments, analyzed the effects of different inertance tube combinations on the cryocooler’s performance. The optimal operation frequency, power factor, no-load cooling temperature, cooling capacity and rCOP were compared for cryocoolers with different inertance tube combinations. After preliminary optimization, the cryocooler achieved 586 mW/20 K cooling power with a total electric power consumption of 185 W, resulting in a rCOP of 4.43%.

IOP Conference Series Materials Science and EngineeringVol. 1327(1)
Technical Institute of Physics and Chemistry (CN), University of Chinese Academy of Sciences (CN)
Openalex Percentile: Top 74%
Advanced Thermodynamic Systems and Engines
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental optimization of phase for a 20 K thermally-coupled two-stage high-frequency pulse tube cryocooler — Miguang Zhao, Yanen Li, et al. · IOP Conference Series Materials Science and Engineering (2025) | TGRS Research Map | TGRS