Impact of wind loads on the structural integrity of reinforced concrete (RC) minarets

The rapid climatic shifts caused by global warming represent a growing and serious threat that demands immediate global attention and preparation. The collapse of minarets in Mersin, İzmir, Ankara and Kahramanmaraş due to strong winds has served as the inspiration for this research article. These incidents highlight the lack of sufficient investigation into the wind effects on minarets in Turkey and underscore the presence of minaret structures that may pose significant risks. In the conducted study, the Çamlıca Mosque minarets, the tallest minarets in Turkey, were used as a reference. Finite element analyses were performed using the ANSYS program for three distinct height scenarios: a high height of 107 meters, a medium height of 57 meters, and a low height of 27 meters. The dimensions of the base, pulpit, transition segment and spire parts of the minarets are the same, only the body lengths have been changed. Wind speeds were calculated according to the height of the minarets and the relevant regulation TS498 data was considered. The research concluded that the minaret with a body height of 20 meters, considered the lowest, was the safest under the influence of strong winds, experiencing a displacement of approximately 9.1 mm at the top. However, it was observed that the displacement values for the medium-height (57 m) and tall (107 m) minarets would increase significantly, with a high risk of structural collapse occurring at the transition segments. In the study, where principal tensile and compressive stress were also calculated and presented, it was found that the tensile stress in the lowest minaret was around 1.5 MPa. However, this value increased significantly in the medium and tallest minarets, rising to approximately 6.5 times and 25 times higher, respectively.

Authors

Institutions

Publication Details

Journal
Gümüşhane Üniversitesi Fen Bilimleri Enstitüsü Dergisi
Published
2025-03-15
DOI
https://doi.org/10.17714/gumusfenbil.1625918
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of wind loads on the structural integrity of reinforced concrete (RC) minarets

Muhammet Karabulut
Gümüşhane Üniversitesi Fen Bilimleri Enstitüsü Dergisi
Masonry and Concrete Structural Analysis
article

Impact of wind loads on the structural integrity of reinforced concrete (RC) minarets

Muhammet Karabulut
article en

Abstract

The rapid climatic shifts caused by global warming represent a growing and serious threat that demands immediate global attention and preparation. The collapse of minarets in Mersin, İzmir, Ankara and Kahramanmaraş due to strong winds has served as the inspiration for this research article. These incidents highlight the lack of sufficient investigation into the wind effects on minarets in Turkey and underscore the presence of minaret structures that may pose significant risks. In the conducted study, the Çamlıca Mosque minarets, the tallest minarets in Turkey, were used as a reference. Finite element analyses were performed using the ANSYS program for three distinct height scenarios: a high height of 107 meters, a medium height of 57 meters, and a low height of 27 meters. The dimensions of the base, pulpit, transition segment and spire parts of the minarets are the same, only the body lengths have been changed. Wind speeds were calculated according to the height of the minarets and the relevant regulation TS498 data was considered. The research concluded that the minaret with a body height of 20 meters, considered the lowest, was the safest under the influence of strong winds, experiencing a displacement of approximately 9.1 mm at the top. However, it was observed that the displacement values for the medium-height (57 m) and tall (107 m) minarets would increase significantly, with a high risk of structural collapse occurring at the transition segments. In the study, where principal tensile and compressive stress were also calculated and presented, it was found that the tensile stress in the lowest minaret was around 1.5 MPa. However, this value increased significantly in the medium and tallest minarets, rising to approximately 6.5 times and 25 times higher, respectively.

Gümüşhane Üniversitesi Fen Bilimleri Enstitüsü DergisiVol. 15(1)
Zonguldak Bülent Ecevit University (TR)
Technische Universität Berlin
Openalex Percentile: Top 88%
Masonry and Concrete Structural Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.