Phoneme discrimination and localization performance in children with cochlear implants and contralateral auditory brainstem implants with inner ear malformations
While the performance of CI alone and bilateral PD is similar, there is a significant difference between the performance of ABI alone and bilateral PD. Therefore, in cases with an ABI, bilateral stimulation should be maintained by continued use of a CI in the contralateral ear, even in the presence of severe inner ear malformation and/or cochlear nerve deficiencies. In the long term, comparable levels of PD discrimination and localization performance can be achieved by using two different modalities.
Authors
- Gonca Sennaroğlu (ORCID: https://orcid.org/0000-0002-3337-2391)
- Levent Sennaroğlu (ORCID: https://orcid.org/0000-0001-8429-2431)
- Erva Değirmenci Uzun (ORCID: https://orcid.org/0000-0002-8745-2776)
- Merve Özbal Batuk (ORCID: https://orcid.org/0000-0003-4771-8127)
Institutions
- Izmir University (TR)
- Bakırçay Üniversitesi
- Hacettepe University (TR)
Publication Details
- Journal
- European Archives of Oto-Rhino-Laryngology
- Published
- 2025-05-30
- DOI
- https://doi.org/10.1007/s00405-025-09474-x
- Primary Topic
- Hearing Loss and Rehabilitation
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
- Hacettepe Üniversitesi