Chiller power consumption forecasting for commercial building based on hybrid convolution neural networks-long short-term memory model with barnacles mating optimizer

This paper addresses the critical challenge of energy efficiency in commercial buildings, where chillers typically consume 40–50% of total building energy. Accurate forecasting of chiller power consumption is essential for optimizing building energy management systems and reducing operational costs. Despite advances in deep learning, existing forecasting models often struggle with the complex temporal dependencies and non-linear patterns in chiller operation data. This paper presents an innovative approach using a hybrid Convolutional Neural Network-Long Short-Term Memory (CNN-LSTM) model optimized by the Barnacles Mating Optimizer (BMO). The study compares the proposed CNN-LSTM-BMO against other metaheuristic optimization algorithms, including Genetic Algorithm (GA), Particle Swarm Optimization (PSO), Ant Colony Optimization (ACO), and Differential Evolution (DE). The models were evaluated using comprehensive performance metrics and validated through statistical analysis. Results demonstrate that the CNN-LSTM-BMO achieves superior performance with the lowest Root Mean Square Error (RMSE) of 0.5523 and highest R ² value of 0.9435, showing statistically significant improvements over other optimization methods as confirmed by paired t -tests ( P < 0.05). Key observations include: (1) the CNN-LSTM-BMO model converges 27% faster than traditional optimization methods; (2) SHapley Additive exPlanations (SHAP) analysis reveals that temperature-related features, particularly saturation temperature, are the most influential predictors across all models; and (3) the proposed model maintains prediction accuracy even under varying operational conditions. The proposed CNN-LSTM-BMO model demonstrates robust convergence characteristics and superior generalization capability, making it particularly suitable for real-world applications in building energy management systems. This research contributes to the advancement of accurate and efficient chiller power consumption forecasting methodologies, offering practical implications for Heating, Ventilation, and Air Conditioning (HVAC) system optimization and energy efficiency improvements in commercial buildings.

Authors

Publication Details

Journal
Next Energy
Published
2025-05-30
DOI
https://doi.org/10.1016/j.nxener.2025.100321
Citations
5
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
5.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Chiller power consumption forecasting for commercial building based on hybrid convolution neural networks-long short-term memory model with barnacles mating optimizer

Zuriani Mustaffa, Mohd Herwan Sulaiman
5 citations
Next Energy
Building Energy and Comfort Optimization
5.03
article

Chiller power consumption forecasting for commercial building based on hybrid convolution neural networks-long short-term memory model with barnacles mating optimizer

Zuriani Mustaffa, Mohd Herwan Sulaiman
article en
5 citations

Abstract

This paper addresses the critical challenge of energy efficiency in commercial buildings, where chillers typically consume 40–50% of total building energy. Accurate forecasting of chiller power consumption is essential for optimizing building energy management systems and reducing operational costs. Despite advances in deep learning, existing forecasting models often struggle with the complex temporal dependencies and non-linear patterns in chiller operation data. This paper presents an innovative approach using a hybrid Convolutional Neural Network-Long Short-Term Memory (CNN-LSTM) model optimized by the Barnacles Mating Optimizer (BMO). The study compares the proposed CNN-LSTM-BMO against other metaheuristic optimization algorithms, including Genetic Algorithm (GA), Particle Swarm Optimization (PSO), Ant Colony Optimization (ACO), and Differential Evolution (DE). The models were evaluated using comprehensive performance metrics and validated through statistical analysis. Results demonstrate that the CNN-LSTM-BMO achieves superior performance with the lowest Root Mean Square Error (RMSE) of 0.5523 and highest R ² value of 0.9435, showing statistically significant improvements over other optimization methods as confirmed by paired t -tests ( P < 0.05). Key observations include: (1) the CNN-LSTM-BMO model converges 27% faster than traditional optimization methods; (2) SHapley Additive exPlanations (SHAP) analysis reveals that temperature-related features, particularly saturation temperature, are the most influential predictors across all models; and (3) the proposed model maintains prediction accuracy even under varying operational conditions. The proposed CNN-LSTM-BMO model demonstrates robust convergence characteristics and superior generalization capability, making it particularly suitable for real-world applications in building energy management systems. This research contributes to the advancement of accurate and efficient chiller power consumption forecasting methodologies, offering practical implications for Heating, Ventilation, and Air Conditioning (HVAC) system optimization and energy efficiency improvements in commercial buildings.

Next EnergyVol. 8
Universiti Malaysia Pahang
Affordable and clean energy
Openalex Percentile: Top 5%
Building Energy and Comfort Optimization
5.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.