Analysis of glucose concentrations in blood solutions using FTIR and Raman spectroscopy methods

The current market provides a range of invasive technologies for measuring blood glucose levels. These invasive methods often lead to discomfort, require significant time investment, and incur high costs, highlighting the urgent need for innovative and more effective glucose measurement techniques. Non-invasive blood glucose measurement (NGM) poses considerable challenges for both academic and industrial sectors. Presently, there is a notable increase in the application of electrical and optical devices in the medical field for clinical and research purposes. Additionally, advancements in Fourier transform infrared (FTIR) spectroscopy and Raman spectroscopy have been made. This study utilizes a combined approach of FTIR and Raman spectroscopy to identify and differentiate the molecular bonds between glucose and hemoglobin, specifically within the wavenumber range of 4000 cm<sup>-1</sup> to 400 cm<sup>-1</sup>. Distinct variations in atomic types and bonding characteristics are observed across different wavenumber ranges. The experiments conducted in this study employed invasive blood samples, with FTIR spectroscopy performed on a potassium bromide tablet, while Raman spectroscopy was conducted on a glass slide. The analysis of the experimental results reveals that as blood glucose concentration increases, the intensity of absorption and the area of the FTIR spectrum decrease, whereas the intensity of Raman signals and the area under the curve increase. These observed decreases and increases are believed to be related to the formation of new hydrogen bonds, as well as a reduction in scattering and an enhancement of Raman intensity following the dissolution of glucose in the bloodstream.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-05-30
DOI
https://doi.org/10.1364/boe.561552
Citations
4
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
6.54
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of glucose concentrations in blood solutions using FTIR and Raman spectroscopy methods

Mahdi Shayganmanesh, Ehsan Azimzadeh Andarabi, Mohadeseh Haji Abdolvahab, Shahab Norouzian-Alam
4 citations
Biomedical Optics Express
Spectroscopy Techniques in Biomedical and Chemical Research
6.54
article

Analysis of glucose concentrations in blood solutions using FTIR and Raman spectroscopy methods

Mahdi Shayganmanesh, Ehsan Azimzadeh Andarabi, Mohadeseh Haji Abdolvahab, Shahab Norouzian-Alam
article en
4 citations

Abstract

The current market provides a range of invasive technologies for measuring blood glucose levels. These invasive methods often lead to discomfort, require significant time investment, and incur high costs, highlighting the urgent need for innovative and more effective glucose measurement techniques. Non-invasive blood glucose measurement (NGM) poses considerable challenges for both academic and industrial sectors. Presently, there is a notable increase in the application of electrical and optical devices in the medical field for clinical and research purposes. Additionally, advancements in Fourier transform infrared (FTIR) spectroscopy and Raman spectroscopy have been made. This study utilizes a combined approach of FTIR and Raman spectroscopy to identify and differentiate the molecular bonds between glucose and hemoglobin, specifically within the wavenumber range of 4000 cm<sup>-1</sup> to 400 cm<sup>-1</sup>. Distinct variations in atomic types and bonding characteristics are observed across different wavenumber ranges. The experiments conducted in this study employed invasive blood samples, with FTIR spectroscopy performed on a potassium bromide tablet, while Raman spectroscopy was conducted on a glass slide. The analysis of the experimental results reveals that as blood glucose concentration increases, the intensity of absorption and the area of the FTIR spectrum decrease, whereas the intensity of Raman signals and the area under the curve increase. These observed decreases and increases are believed to be related to the formation of new hydrogen bonds, as well as a reduction in scattering and an enhancement of Raman intensity following the dissolution of glucose in the bloodstream.

Biomedical Optics ExpressVol. 16(7)
Motamed Cancer Institute (IR), Iran University of Science and Technology (IR)
Zero hunger
Openalex Percentile: Top 4%
Spectroscopy Techniques in Biomedical and Chemical Research
6.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of glucose concentrations in blood solutions using FTIR and Raman spectroscopy methods — Mahdi Shayganmanesh, Ehsan Azimzadeh Andarabi, et al. · Biomedical Optics Express (2025) | TGRS Research Map | TGRS