PERFORMANCE COMPARISON OF BUILDINGS WITH SHEAR WALL SYSTEM AND VISCOUS DAMPERS

This study was conducted to evaluate the stability and performance of a building using a shear wall system with a building that applies FVD as a seismic damper system. The stability parameters analyzed include displacement, drift ratio, and storey drift. Meanwhile, the structural performance is analyzed based on the number of phases, hysteresis energy generated, and structural performance level. Numerical modeling of the building structure was conducted, and then earthquake loading simulations were carried out using ChiChi, Kobe, and Yushu earthquakes that had been scaled according to the dynamic response analysis procedure. The results show that the use of FVD as an energy dissipation system has significant potential in improving the performance and stability of structures. The performance of this system is shown to match, and in some aspects even compete, the effectiveness of shear walls in reducing the seismic response of building structures. Therefore, FVDs can be considered an efficient alternative in earthquake-resistant building design, especially in structures that require higher flexibility without sacrificing energy dissipation capacity.

Authors

Institutions

Publication Details

Journal
Jurnal PenSil
Published
2025-05-30
DOI
https://doi.org/10.21009/jpensil.v14i2.53909
Primary Topic
Structural Engineering and Vibration Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PERFORMANCE COMPARISON OF BUILDINGS WITH SHEAR WALL SYSTEM AND VISCOUS DAMPERS

Aulia Indira Kumalasari, Erwin Rommel, Alfin Bena Tedha
Jurnal PenSil
Structural Engineering and Vibration Analysis
article

PERFORMANCE COMPARISON OF BUILDINGS WITH SHEAR WALL SYSTEM AND VISCOUS DAMPERS

Aulia Indira Kumalasari, Erwin Rommel, Alfin Bena Tedha
article en

Abstract

This study was conducted to evaluate the stability and performance of a building using a shear wall system with a building that applies FVD as a seismic damper system. The stability parameters analyzed include displacement, drift ratio, and storey drift. Meanwhile, the structural performance is analyzed based on the number of phases, hysteresis energy generated, and structural performance level. Numerical modeling of the building structure was conducted, and then earthquake loading simulations were carried out using ChiChi, Kobe, and Yushu earthquakes that had been scaled according to the dynamic response analysis procedure. The results show that the use of FVD as an energy dissipation system has significant potential in improving the performance and stability of structures. The performance of this system is shown to match, and in some aspects even compete, the effectiveness of shear walls in reducing the seismic response of building structures. Therefore, FVDs can be considered an efficient alternative in earthquake-resistant building design, especially in structures that require higher flexibility without sacrificing energy dissipation capacity.

Jurnal PenSilVol. 14(2)
Universitas Muhammadiyah Malang (ID), Universitas Muhammadiyah Jember (ID)
Openalex Percentile: Top 88%
Structural Engineering and Vibration Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.