Focus-tunable two-photon fiberscope enabling <i>in vivo</i> imaging at selected depths

Miniaturized two-photon (2P) imaging devices enable real-time <i>in vivo</i> and <i>in situ</i> imaging at subcellular resolution, highly valuable for clinical applications and basic research (such as neuroscience). However, achieving high-quality volumetric imaging at varying depths remains challenging. In this study, we demonstrated a 2P fiberscope capable of three-dimensional (3D) imaging over a cylindrical volume of a 350 μm diameter and a 400 μm depth. Depth scanning was achieved by incorporating a miniature electrowetting-based varioptic lens (VL) into a two-dimensional (2D) scanning 2P fiberscope, whose focus was tuned by modulating the VL drive voltage. The performance of the fiberscope was demonstrated by <i>ex vivo</i> imaging of fluorescently stained convallaria and GFP mouse brain sections, as well as <i>in vivo</i> dynamic GCaMP-based calcium imaging of cortical neurons in an awake mouse.

Authors

Publication Details

Journal
Optics Letters
Published
2025-05-30
DOI
https://doi.org/10.1364/ol.560869
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Focus-tunable two-photon fiberscope enabling in vivo imaging at selected depths

Xingde Li, J. Huang, Yuehan Liu
Optics Letters
Advanced Fluorescence Microscopy Techniques
article

Focus-tunable two-photon fiberscope enabling in vivo imaging at selected depths

Xingde Li, J. Huang, Yuehan Liu
article en

Abstract

Miniaturized two-photon (2P) imaging devices enable real-time <i>in vivo</i> and <i>in situ</i> imaging at subcellular resolution, highly valuable for clinical applications and basic research (such as neuroscience). However, achieving high-quality volumetric imaging at varying depths remains challenging. In this study, we demonstrated a 2P fiberscope capable of three-dimensional (3D) imaging over a cylindrical volume of a 350 μm diameter and a 400 μm depth. Depth scanning was achieved by incorporating a miniature electrowetting-based varioptic lens (VL) into a two-dimensional (2D) scanning 2P fiberscope, whose focus was tuned by modulating the VL drive voltage. The performance of the fiberscope was demonstrated by <i>ex vivo</i> imaging of fluorescently stained convallaria and GFP mouse brain sections, as well as <i>in vivo</i> dynamic GCaMP-based calcium imaging of cortical neurons in an awake mouse.

Optics LettersVol. 50(13)
National Institutes of Health
Openalex Percentile: Top 91%
Advanced Fluorescence Microscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Focus-tunable two-photon fiberscope enabling <i>in vivo</i> imaging at selected depths — Xingde Li, J. Huang, et al. · Optics Letters (2025) | TGRS Research Map | TGRS