Development and validation of an innovative HPLC-UV method for determination of Metalaxyl-M in flowable suspension fungicide formulas

Metalaxyl-M is a modern and more efficient version of metalaxyl which is designated to provide effective control of damaging fungal diseases. This work aimed to develop and validate a low-cost, accurate, fast, and simple analytical method for determination of active ingredient metalaxyl-M using high-performance liquid chromatography with ultraviolet detection (HPLC-UV). The development of the novel method was performed on reversed-phase brownlee™ C-18 column at constant temperature 30 ºC. The mobile phase consists of acetonitrile and distilled water in volumetric ratio 62.5:37.5, a flow rate of 1.2 mL/min, and the detective wavelength at 270 nm. The validation protocol underscore in our study was SANCO/3030/99 rev. 5. Specificity, linearity, LOD, LOQ, precision, recovery, and accuracy parameters were calculated and discussed. The values for multiple correlation coefficient (R2 ≥ 0.990), relative standard deviation (RSD < 1.5 %), recoveries ranged from (99.21 - 101.16 %) were found within acceptance criteria.

Authors

Publication Details

Journal
Current Chemistry Letters
Published
2025-01-01
DOI
https://doi.org/10.5267/j.ccl.2025.4.001
Citations
2
Primary Topic
Pesticide Residue Analysis and Safety
Type
article
Field-Weighted Citation Impact
2.32
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of an innovative HPLC-UV method for determination of Metalaxyl-M in flowable suspension fungicide formulas

Ismael M. Elkamhawy
2 citations
Current Chemistry Letters
Pesticide Residue Analysis and Safety
2.32
article

Development and validation of an innovative HPLC-UV method for determination of Metalaxyl-M in flowable suspension fungicide formulas

Ismael M. Elkamhawy
article en
2 citations

Abstract

Metalaxyl-M is a modern and more efficient version of metalaxyl which is designated to provide effective control of damaging fungal diseases. This work aimed to develop and validate a low-cost, accurate, fast, and simple analytical method for determination of active ingredient metalaxyl-M using high-performance liquid chromatography with ultraviolet detection (HPLC-UV). The development of the novel method was performed on reversed-phase brownlee™ C-18 column at constant temperature 30 ºC. The mobile phase consists of acetonitrile and distilled water in volumetric ratio 62.5:37.5, a flow rate of 1.2 mL/min, and the detective wavelength at 270 nm. The validation protocol underscore in our study was SANCO/3030/99 rev. 5. Specificity, linearity, LOD, LOQ, precision, recovery, and accuracy parameters were calculated and discussed. The values for multiple correlation coefficient (R2 ≥ 0.990), relative standard deviation (RSD < 1.5 %), recoveries ranged from (99.21 - 101.16 %) were found within acceptance criteria.

Current Chemistry LettersVol. 14(3)
Openalex Percentile: Top 13%
Pesticide Residue Analysis and Safety
2.32
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and validation of an innovative HPLC-UV method for determination of Metalaxyl-M in flowable suspension fungicide formulas — Ismael M. Elkamhawy · Current Chemistry Letters (2025) | TGRS Research Map | TGRS