Determination of Nifuratel in Human Plasma by Using Liquid Chromatography-Tandem Mass Spectrometry and Its Application to a Pharmacokinetic Study

In this study, a rapid, straightforward, and sensitive method was developed and validated for the quantification of nifuratel (NIF) in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Plasma samples were processed using liquid-liquid extraction with nifuratel 13C D3 as the internal standard (IS). Chromatographic separation was achieved on a Waters ACQUITY UPLC BEH C18 (1.7 µm, 2.1 × 50 mm) column using a mobile phase consisting of formic acid, water, and acetonitrile at a flow rate of 0.60 mL/min. NIF was identified and quantified via mass spectrometry with electrospray ionization (ESI) in positive ion mode and multiple reaction monitoring (MRM). The method showed linearity in the range of 0.25 - 150 ng/mL for NIF. The developed and validated method was applied to the bioequivalence study in human plasma samples.

Authors

Institutions

Publication Details

Journal
Open Journal of Applied Sciences
Published
2025-01-01
DOI
https://doi.org/10.4236/ojapps.2025.155103
Primary Topic
Antibiotics Pharmacokinetics and Efficacy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Nifuratel in Human Plasma by Using Liquid Chromatography-Tandem Mass Spectrometry and Its Application to a Pharmacokinetic Study

Onursal Sağlam, Gökçe Demiray, Nihal Saraner, Berrak Güney
Open Journal of Applied Sciences
Antibiotics Pharmacokinetics and Efficacy
article

Determination of Nifuratel in Human Plasma by Using Liquid Chromatography-Tandem Mass Spectrometry and Its Application to a Pharmacokinetic Study

Onursal Sağlam, Gökçe Demiray, Nihal Saraner, Berrak Güney
article en

Abstract

In this study, a rapid, straightforward, and sensitive method was developed and validated for the quantification of nifuratel (NIF) in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Plasma samples were processed using liquid-liquid extraction with nifuratel 13C D3 as the internal standard (IS). Chromatographic separation was achieved on a Waters ACQUITY UPLC BEH C18 (1.7 µm, 2.1 × 50 mm) column using a mobile phase consisting of formic acid, water, and acetonitrile at a flow rate of 0.60 mL/min. NIF was identified and quantified via mass spectrometry with electrospray ionization (ESI) in positive ion mode and multiple reaction monitoring (MRM). The method showed linearity in the range of 0.25 - 150 ng/mL for NIF. The developed and validated method was applied to the bioequivalence study in human plasma samples.

Open Journal of Applied SciencesVol. 15(05)
Bioanalytica (Switzerland) (CH)
Openalex Percentile: Top 86%
Antibiotics Pharmacokinetics and Efficacy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.