In-vitro Evaluation of Force Decay in Thermoplastic and Thermoset Elastomeric Chains of the Same Brand

Objectives: To evaluate and compare the force decay of short-link transparent thermoplastic and thermoset elastomeric chains from American Orthodontics. Materials and Methods: Thirty-three-link chain segments (with one link at each end for easy handling) were assigned to two groups: 15 thermoplastic chains and 15 thermoset chains. Initial force values were measured using an MTS Universal Testing Machine. Each group was then stretched to 20 mm (double its original length) and immersed in containers with artificial saliva at 37°C. The chains were removed at 24 hours, 7, 14 and 21 days to measure force decay and analyze statistical results. Results: Thermoplastic chains exhibited a 9.46% greater force decay than thermoset chains at the end of the 21-day study. The greatest force loss in both groups occurred within the first 24 hours. Conclusion: Thermoset elastomeric chains maintain more stable and consistent force values compared to thermoplastic chains, indicating their greater effectiveness in orthodontic treatments. A clear distinction should be made between these two types of chains, as each performs differently in terms of force decay.

Authors

Publication Details

Journal
Journal of Dental Health and Oral Research
Published
2025-05-29
DOI
https://doi.org/10.46889/jdhor.2025.6204
Primary Topic
Polymer Foaming and Composites
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In-vitro Evaluation of Force Decay in Thermoplastic and Thermoset Elastomeric Chains of the Same Brand

Jessika V. Rojas
Journal of Dental Health and Oral Research
Polymer Foaming and Composites
article

In-vitro Evaluation of Force Decay in Thermoplastic and Thermoset Elastomeric Chains of the Same Brand

Jessika V. Rojas
article en

Abstract

Objectives: To evaluate and compare the force decay of short-link transparent thermoplastic and thermoset elastomeric chains from American Orthodontics. Materials and Methods: Thirty-three-link chain segments (with one link at each end for easy handling) were assigned to two groups: 15 thermoplastic chains and 15 thermoset chains. Initial force values were measured using an MTS Universal Testing Machine. Each group was then stretched to 20 mm (double its original length) and immersed in containers with artificial saliva at 37°C. The chains were removed at 24 hours, 7, 14 and 21 days to measure force decay and analyze statistical results. Results: Thermoplastic chains exhibited a 9.46% greater force decay than thermoset chains at the end of the 21-day study. The greatest force loss in both groups occurred within the first 24 hours. Conclusion: Thermoset elastomeric chains maintain more stable and consistent force values compared to thermoplastic chains, indicating their greater effectiveness in orthodontic treatments. A clear distinction should be made between these two types of chains, as each performs differently in terms of force decay.

Journal of Dental Health and Oral Research
Openalex Percentile: Top 90%
Polymer Foaming and Composites
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

In-vitro Evaluation of Force Decay in Thermoplastic and Thermoset Elastomeric Chains of the Same Brand — Jessika V. Rojas · Journal of Dental Health and Oral Research (2025) | TGRS Research Map | TGRS