The impact of radiation dose variability on the response of radiophotoluminescence glass dosimeters – an experimental approach

The dosimetric properties of radiophotoluminescence glass dosimeters (RPLGDs) make them valuable tools for accurately measuring doses in various radiation fields. Over the years, thermoluminescence dosimeters have been used for both personal and environmental monitoring in South Africa, although they have certain limitations. We investigated the exceptional properties of RPLGDs by characterising their response to different radiation doses, using radiation sources of 60Co, 137Cs, and 241Am. The objective was to assess the ability of RPLGDs to be read multiple times without losing the original signal, and to explore their potential to replace TLDs in diverse radiation environments. A substitution method was employed to determine the reference measurements across all radiation source set-ups. In this approach, the RPLGD, serving as the unit under test, was exposed to the same dose as the ionisation chambers, which acted as reference detectors to accumulate the radiation signal, which was then corrected to determine the air kerma and absorbed dose to water. All relevant corrections affecting the unit under test response were applied to the final readings to characterise the RPLGDs, which were compared with the prescribed dose. The findings of this research are valuable to medical facilities and radiation workers as they offer both technical and economic benefits through improving the accuracy and reliability of radiation dose monitoring.

Authors

Institutions

Publication Details

Journal
South African Journal of Science
Published
2025-05-29
DOI
https://doi.org/10.17159/sajs.2025/17896
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The impact of radiation dose variability on the response of radiophotoluminescence glass dosimeters – an experimental approach

Manny Mathuthu, Humbulani V. Maselesele, Samuel Odumu Ogana John, Dithole H. Seepamore
South African Journal of Science
Advanced Radiotherapy Techniques
article

The impact of radiation dose variability on the response of radiophotoluminescence glass dosimeters – an experimental approach

Manny Mathuthu, Humbulani V. Maselesele, Samuel Odumu Ogana John, Dithole H. Seepamore
article en

Abstract

The dosimetric properties of radiophotoluminescence glass dosimeters (RPLGDs) make them valuable tools for accurately measuring doses in various radiation fields. Over the years, thermoluminescence dosimeters have been used for both personal and environmental monitoring in South Africa, although they have certain limitations. We investigated the exceptional properties of RPLGDs by characterising their response to different radiation doses, using radiation sources of 60Co, 137Cs, and 241Am. The objective was to assess the ability of RPLGDs to be read multiple times without losing the original signal, and to explore their potential to replace TLDs in diverse radiation environments. A substitution method was employed to determine the reference measurements across all radiation source set-ups. In this approach, the RPLGD, serving as the unit under test, was exposed to the same dose as the ionisation chambers, which acted as reference detectors to accumulate the radiation signal, which was then corrected to determine the air kerma and absorbed dose to water. All relevant corrections affecting the unit under test response were applied to the final readings to characterise the RPLGDs, which were compared with the prescribed dose. The findings of this research are valuable to medical facilities and radiation workers as they offer both technical and economic benefits through improving the accuracy and reliability of radiation dose monitoring.

South African Journal of ScienceVol. 121(5/6)
North-West University (ZA), Steve Biko Hospital (ZA), National Metrology Institute of South Africa (ZA)
Openalex Percentile: Top 82%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The impact of radiation dose variability on the response of radiophotoluminescence glass dosimeters – an experimental approach — Manny Mathuthu, Humbulani V. Maselesele, et al. · South African Journal of Science (2025) | TGRS Research Map | TGRS