Open Path Spectroscopic Detection of Hydroxyl Radical: A Comparison between Broadband Cavity-Enhanced Absorption Spectroscopy (BBCEAS) and BBCEAS Coupled with a Fabry–Pérot Interferometer (BBCEAS-FP)

Hydroxyl radical (OH) is the primary atmospheric oxidant, but it is challenging to measure due to its short half-life under atmospheric conditions (approximately 1 s) and low ambient concentrations (approximately 10<sup>6</sup> molecules/cm<sup>3</sup>). While several measurement techniques exist, including laser-induced fluorescence with fluorescence assay by gas expansion (LIF-FAGE), differential optical absorption spectroscopy, and chemical ionization mass spectrometry (CIMS), often only LIF-FAGE and CIMS are considered available for field measurements. This study compares the performance of two instruments: a broadband cavity-enhanced absorption spectroscopy (BBCEAS) coupled with a CCD and a BBCEAS coupled with a Fabry-Pérot interferometer (BBCEAS-FP). The semiportable BBCEAS instrument benefits from spectroscopic specificity, avoiding interference from other species, and features inherent calibration, eliminating calibration errors. The effects of aerosols and turbulence on performance were also evaluated. A low-loss optic was used to measure the optical cavity reflectivity in an open-path configuration, and a butane flame served as the OH source during testing. The BBCEAS instrument achieved an extrapolated 1-h detection limit (1σ) of 1.5 × 10<sup>7</sup> molecules/cm<sup>3</sup> for ambient-temperature OH. Applying a Gauss-Hermite filter reduced noise in the extinction spectrum by 2.66 times, lowering the extrapolated detection limit to 4.6 × 10<sup>6</sup> molecules/cm<sup>3</sup>. The BBCEAS-FP, a more cost-effective and portable instrument, demonstrated a comparable extrapolated 1-h (1σ) detection limit of 1.5 × 10<sup>7</sup> molecules/cm<sup>3</sup>.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-05-29
DOI
https://doi.org/10.1021/acs.analchem.5c01515
Citations
4
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
3.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Open Path Spectroscopic Detection of Hydroxyl Radical: A Comparison between Broadband Cavity-Enhanced Absorption Spectroscopy (BBCEAS) and BBCEAS Coupled with a Fabry–Pérot Interferometer (BBCEAS-FP)

Jaron C. Hansen, Matthew C. Asplund, Philip Lundrigan, Ryan Thalman et al.
4 citations
Analytical Chemistry
Spectroscopy and Laser Applications
3.03
article

Open Path Spectroscopic Detection of Hydroxyl Radical: A Comparison between Broadband Cavity-Enhanced Absorption Spectroscopy (BBCEAS) and BBCEAS Coupled with a Fabry–Pérot Interferometer (BBCEAS-FP)

Jaron C. Hansen, Matthew C. Asplund, Philip Lundrigan, Ryan Thalman, Alan M. Cook, Callum E. Flowerday, Samuel A. Badstubner
article en
4 citations

Abstract

Hydroxyl radical (OH) is the primary atmospheric oxidant, but it is challenging to measure due to its short half-life under atmospheric conditions (approximately 1 s) and low ambient concentrations (approximately 10<sup>6</sup> molecules/cm<sup>3</sup>). While several measurement techniques exist, including laser-induced fluorescence with fluorescence assay by gas expansion (LIF-FAGE), differential optical absorption spectroscopy, and chemical ionization mass spectrometry (CIMS), often only LIF-FAGE and CIMS are considered available for field measurements. This study compares the performance of two instruments: a broadband cavity-enhanced absorption spectroscopy (BBCEAS) coupled with a CCD and a BBCEAS coupled with a Fabry-Pérot interferometer (BBCEAS-FP). The semiportable BBCEAS instrument benefits from spectroscopic specificity, avoiding interference from other species, and features inherent calibration, eliminating calibration errors. The effects of aerosols and turbulence on performance were also evaluated. A low-loss optic was used to measure the optical cavity reflectivity in an open-path configuration, and a butane flame served as the OH source during testing. The BBCEAS instrument achieved an extrapolated 1-h detection limit (1σ) of 1.5 × 10<sup>7</sup> molecules/cm<sup>3</sup> for ambient-temperature OH. Applying a Gauss-Hermite filter reduced noise in the extinction spectrum by 2.66 times, lowering the extrapolated detection limit to 4.6 × 10<sup>6</sup> molecules/cm<sup>3</sup>. The BBCEAS-FP, a more cost-effective and portable instrument, demonstrated a comparable extrapolated 1-h (1σ) detection limit of 1.5 × 10<sup>7</sup> molecules/cm<sup>3</sup>.

Analytical ChemistryVol. 97(22)
Brigham Young University (US), Snow College (US)
National Science Foundation
Openalex Percentile: Top 9%
Spectroscopy and Laser Applications
3.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.