Mid-infrared acetone gas sensors using substrate-integrated hollow waveguides augmented by advanced preconcentrators

The identification of volatile organic compounds (VOC) such as acetone, a relevant biomarker for diabetes mellitus in exhaled human breath has become essential for early disease diagnostics, prognosis, and monitoring of metabolic responses to pharmacological interventions. Gas chromatography coupled with mass spectrometry (GC-MS) is considered as the gold standard for breath analysis. However, its inability to offer point-of-care monitoring limits its applicability in clinical environments. Optical techniques based on absorption in the mid-infrared range (2.5 to 25 μm) appear as promising alternatives due to their inherent selectivity, potential for miniaturization, portability, and direct analysis with rapid response. Relevant biomarkers present in exhaled breath, are usually observed in the ppb to ppm (v/v) concentration regime. For sensitivity enhancement of optical sensing techniques, appropriate preconcentration schemes are required prior to the optical detection. The present study describes a method combining a multi-channel substrate-integrated preconcentration module (a.k.a., muciPRECON) for enhancing and optimizing the detection of acetone via a mid-infrared photonic sensing system. The sensor system comprises a compact Fourier Transform Infrared (FTIR) spectrometer, a technique that enables detailed infrared spectral analysis, coupled to a substrate-integrated hollow waveguide (iHWG) simultaneously acting as a gas cell and as a photon conduit. Preconcentation experiments were from acetone/nitrogen gas mixtures in the concentration range of 5-100 ppm at - 10 °C followed by desorption at a temperature of 100 °C and direct injection into the IR sensing system Thus obtained acetone spectra were quantified evaluating a molecule-specific vibrational absorption peak area in the spectral window 1260-1170 cm<sup>-1</sup>. After extensive screening, Tenax was identified as superior sorbent material providing an enrichment factor of up to 153-times, a limit of detection (LOD) of 0.118 ppm, and a limit of quantification (LOQ) of 0.393 ppm. These results are indeed promising for practical applications, especially since acetone concentrations usually vary between 0.3 and 0.9 ppmv within the exhaled breath of healthy individuals, and in individuals with diabetes, acetone concentrations are typically around 1.7 to 3.0 ppmv. Consequently, the developed systems have the necessary sensitivity and accuracy to detect acetone levels that are in the relevant physiological range indicating their potential use in future real-world scenarios.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-05-29
DOI
https://doi.org/10.1038/s41598-025-02514-w
Citations
1
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mid-infrared acetone gas sensors using substrate-integrated hollow waveguides augmented by advanced preconcentrators

Diandra Nunes Barreto, João Flávio da Silveira Petruci, Vjekoslav Kokoric, Boris Mizaikoff et al.
1 citations
Scientific Reports
Advanced Chemical Sensor Technologies
0.67
article

Mid-infrared acetone gas sensors using substrate-integrated hollow waveguides augmented by advanced preconcentrators

Diandra Nunes Barreto, João Flávio da Silveira Petruci, Vjekoslav Kokoric, Boris Mizaikoff, C. Schreiber
article en
1 citations

Abstract

The identification of volatile organic compounds (VOC) such as acetone, a relevant biomarker for diabetes mellitus in exhaled human breath has become essential for early disease diagnostics, prognosis, and monitoring of metabolic responses to pharmacological interventions. Gas chromatography coupled with mass spectrometry (GC-MS) is considered as the gold standard for breath analysis. However, its inability to offer point-of-care monitoring limits its applicability in clinical environments. Optical techniques based on absorption in the mid-infrared range (2.5 to 25 μm) appear as promising alternatives due to their inherent selectivity, potential for miniaturization, portability, and direct analysis with rapid response. Relevant biomarkers present in exhaled breath, are usually observed in the ppb to ppm (v/v) concentration regime. For sensitivity enhancement of optical sensing techniques, appropriate preconcentration schemes are required prior to the optical detection. The present study describes a method combining a multi-channel substrate-integrated preconcentration module (a.k.a., muciPRECON) for enhancing and optimizing the detection of acetone via a mid-infrared photonic sensing system. The sensor system comprises a compact Fourier Transform Infrared (FTIR) spectrometer, a technique that enables detailed infrared spectral analysis, coupled to a substrate-integrated hollow waveguide (iHWG) simultaneously acting as a gas cell and as a photon conduit. Preconcentation experiments were from acetone/nitrogen gas mixtures in the concentration range of 5-100 ppm at - 10 °C followed by desorption at a temperature of 100 °C and direct injection into the IR sensing system Thus obtained acetone spectra were quantified evaluating a molecule-specific vibrational absorption peak area in the spectral window 1260-1170 cm<sup>-1</sup>. After extensive screening, Tenax was identified as superior sorbent material providing an enrichment factor of up to 153-times, a limit of detection (LOD) of 0.118 ppm, and a limit of quantification (LOQ) of 0.393 ppm. These results are indeed promising for practical applications, especially since acetone concentrations usually vary between 0.3 and 0.9 ppmv within the exhaled breath of healthy individuals, and in individuals with diabetes, acetone concentrations are typically around 1.7 to 3.0 ppmv. Consequently, the developed systems have the necessary sensitivity and accuracy to detect acetone levels that are in the relevant physiological range indicating their potential use in future real-world scenarios.

Scientific ReportsVol. 15(1)
Universität Ulm (DE), Hahn-Schickard-Gesellschaft für angewandte Forschung (DE), Universidade Federal de Uberlândia (BR)
European Commission, Österreichische Forschungsförderungsgesellschaft, Universität Ulm
Openalex Percentile: Top 31%
Advanced Chemical Sensor Technologies
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.