Modification-Free Oligonucleotide-Utilized Lateral Flow Assay System for On-Site Detection of Foodborne Pathogens

Foodborne infectious diseases are a major public health and economic issue worldwide, warranting an effective food safety management system that can rapidly detect foodborne pathogens. We developed a modification-free lateral flow assay for the specific hybridization (M-FLASH) system using modification-free oligonucleotides that specifically recognize the single-stranded loop region of loop-mediated isothermal amplification (LAMP) products for sensitive and on-site detection of foodborne pathogens. To increase its suitability for field diagnosis, four unique strategies were introduced: (i) thermal lysis for DNA extraction, (ii) direct LAMP without any additional DNA purification steps for DNA amplification, (iii) LFA system where the capture probe is immobilized by our salt-mediated immobilization of nucleic acids (SAIoNs) method, and (iv) reporter probe-gold nanoparticle (AuNP) conjugates prepared by the microwave-assisted heating-dry method. The proposed system relies on sequence-specific hybridization of LAMP products with both the CP in the LFA strip and the reporter probe in AuNPs. It exhibited high specificity without any interference from nontarget pathogens; furthermore, modifications to DNA oligonucleotides were unwarranted, significantly reducing production and assay costs. The system successfully detected <i>Escherichia coli</i> O157:H7 down to 10<sup>1</sup> CFU/mL with an assay time of <2 h and was effective in analyzing target pathogens in artificially contaminated food samples. It also demonstrated universal applicability for detecting <i>Listeria monocytogenes</i> and multiplex detection of <i>E. coli</i> O157:H7 and <i>L. monocytogenes</i>. This system has high potential for use in resource-limited settings and can be used as the core platform for the detection of various pathogenic bacteria or viruses.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-05-29
DOI
https://doi.org/10.1021/acs.analchem.5c00379
Citations
8
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
5.39

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modification-Free Oligonucleotide-Utilized Lateral Flow Assay System for On-Site Detection of Foodborne Pathogens

M.C. Cho, Seokjoon Kim, Byung Seok, Seung Hyeon Reo et al.
8 citations
Analytical Chemistry
Biosensors and Analytical Detection
5.39
article

Modification-Free Oligonucleotide-Utilized Lateral Flow Assay System for On-Site Detection of Foodborne Pathogens

M.C. Cho, Seokjoon Kim, Byung Seok, Seung Hyeon Reo, Seungjin Lee, Ki Soo Park, Eun Sung Lee
article en
8 citations

Abstract

Foodborne infectious diseases are a major public health and economic issue worldwide, warranting an effective food safety management system that can rapidly detect foodborne pathogens. We developed a modification-free lateral flow assay for the specific hybridization (M-FLASH) system using modification-free oligonucleotides that specifically recognize the single-stranded loop region of loop-mediated isothermal amplification (LAMP) products for sensitive and on-site detection of foodborne pathogens. To increase its suitability for field diagnosis, four unique strategies were introduced: (i) thermal lysis for DNA extraction, (ii) direct LAMP without any additional DNA purification steps for DNA amplification, (iii) LFA system where the capture probe is immobilized by our salt-mediated immobilization of nucleic acids (SAIoNs) method, and (iv) reporter probe-gold nanoparticle (AuNP) conjugates prepared by the microwave-assisted heating-dry method. The proposed system relies on sequence-specific hybridization of LAMP products with both the CP in the LFA strip and the reporter probe in AuNPs. It exhibited high specificity without any interference from nontarget pathogens; furthermore, modifications to DNA oligonucleotides were unwarranted, significantly reducing production and assay costs. The system successfully detected <i>Escherichia coli</i> O157:H7 down to 10<sup>1</sup> CFU/mL with an assay time of <2 h and was effective in analyzing target pathogens in artificially contaminated food samples. It also demonstrated universal applicability for detecting <i>Listeria monocytogenes</i> and multiplex detection of <i>E. coli</i> O157:H7 and <i>L. monocytogenes</i>. This system has high potential for use in resource-limited settings and can be used as the core platform for the detection of various pathogenic bacteria or viruses.

Analytical ChemistryVol. 97(27)
Konkuk University Medical Center (KR), Biological E (India) (IN), Advanced Energy Materials (United States) (US)
Ministry of Food and Drug Safety, National Research Foundation of Korea
Zero hunger
Openalex Percentile: Top 4%
Biosensors and Analytical Detection
5.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.