A Performance Indicator for Optimizing Source–Detector Separation in Functional Near‐Infrared Spectroscopy

ABSTRACT The performance of Functional Near‐Infrared Spectroscopy (fNIRS) devices critically depends on the probe design, which affects signal quality, spatial and depth resolution, and data reliability. A critical component of probe separation is source‐to‐detector separation, which is defined as the distance between the light source and the detector. Optimizing this separation is essential for improving the signal‐to‐noise ratio (SNR) and sensitivity at depth (SAD). Larger separations enhance depth resolution, facilitating more accurate assessments of brain activity. Conversely, excessive separation may reduce SNR due to the lower light intensity received by the detector. In this study, a performance indicator was created to optimize separation by integrating the SNR and SAD. A probe was constructed that featured one light source and four detectors mounted on a mechanism that allowed for adjustable separations. A phantom mimicking brain tissue was used. Signals were recorded from the probe positioned on the phantom at various separations, employing light sources emitting light at wavelengths of 730, 800, and 850 nm, and optical power levels of 19, 26, 32, 38, and 44 mW. The SNR values for each separation were computed from the recorded signals, whereas the SAD values were obtained from existing literature. The performance indicator was developed as a weighted sum of SNR and SAD, normalized between 0 and 1, with higher values indicating enhanced probe performance due to optimized separation. The indicator is expected to improve the reliability of fNIRS data; however, further research involving diverse populations is required to validate its practical application.

Authors

Institutions

Publication Details

Journal
International Journal of Imaging Systems and Technology
Published
2025-05-29
DOI
https://doi.org/10.1002/ima.70113
Citations
1
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Performance Indicator for Optimizing Source–Detector Separation in Functional Near‐Infrared Spectroscopy

Serhat Ilgaz Yöner, Gökhan Ertaş
1 citations
International Journal of Imaging Systems and Technology
Optical Imaging and Spectroscopy Techniques
1.36
article

A Performance Indicator for Optimizing Source–Detector Separation in Functional Near‐Infrared Spectroscopy

Serhat Ilgaz Yöner, Gökhan Ertaş
article en
1 citations

Abstract

ABSTRACT The performance of Functional Near‐Infrared Spectroscopy (fNIRS) devices critically depends on the probe design, which affects signal quality, spatial and depth resolution, and data reliability. A critical component of probe separation is source‐to‐detector separation, which is defined as the distance between the light source and the detector. Optimizing this separation is essential for improving the signal‐to‐noise ratio (SNR) and sensitivity at depth (SAD). Larger separations enhance depth resolution, facilitating more accurate assessments of brain activity. Conversely, excessive separation may reduce SNR due to the lower light intensity received by the detector. In this study, a performance indicator was created to optimize separation by integrating the SNR and SAD. A probe was constructed that featured one light source and four detectors mounted on a mechanism that allowed for adjustable separations. A phantom mimicking brain tissue was used. Signals were recorded from the probe positioned on the phantom at various separations, employing light sources emitting light at wavelengths of 730, 800, and 850 nm, and optical power levels of 19, 26, 32, 38, and 44 mW. The SNR values for each separation were computed from the recorded signals, whereas the SAD values were obtained from existing literature. The performance indicator was developed as a weighted sum of SNR and SAD, normalized between 0 and 1, with higher values indicating enhanced probe performance due to optimized separation. The indicator is expected to improve the reliability of fNIRS data; however, further research involving diverse populations is required to validate its practical application.

International Journal of Imaging Systems and TechnologyVol. 35(4)
Yeditepe University (TR), Kent Hastanesi (TR), Acıbadem Adana Hospital (TR), Boğaziçi University (TR)
Drexel University
Affordable and clean energy
Openalex Percentile: Top 20%
Optical Imaging and Spectroscopy Techniques
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.