Rapid and sensitive rGO/AuNP-based electrochemical nano-biosensor for detection of <i>E. coli</i> and <i>S. aureus</i> in less than an hour

Improved diagnostic screening has become critical for bacterial infection identification and prevention. The sensitivity, reliability, repeatability, detection time, and specificity of a test or tool are critical for its translation to application. Electrochemical detection methods are quick and can provide point-of-care diagnosis. We report on reduced graphene oxide/gold (rGO–AuNP) nanocomposites that enabled highly sensitive and quick detection of harmful bacteria, such as E. coli and S. aureus. The technique involved employing rGO as a nano-carrier and Au as a bioactive surface to bind particular antibodies for electrochemical immunoassays. The current approach is culture-independent and does not require sample processing for bacterial detection. It is a pathogen detection technology that uses rGO–AuNP as an electrochemical transducer platform and target particular antibodies for E. coli and S. aureus to obtain improved sensitivity and speed. Differential pulse voltammetry was used to detect infections. These findings demonstrated that rGO–AuNp nanocomposites have up to three times the sensitivity of rGO and AuNP alone. Importantly, the antibody linked bioactive screen-printed electrodes remained stable for more than a month, allowing just electrochemical measurements to be performed at the time of detection. This allowed for pathogen detection in less than an hour. The limit of detection for both E. coli and S. aureus was 2 CFU/ml, making it extremely sensitive. An electrochemical sensor was showing a linear response with R2 0.98. According to the physicochemical evaluation of nanocomposites, the improved sensitivity and stability were caused by a lowered bandgap in composites and uniform distribution of AuNPs on a rGO nano-template.

Authors

Institutions

Publication Details

Journal
AIP Advances
Published
2025-05-01
DOI
https://doi.org/10.1063/5.0243093
Citations
3
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
2.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid and sensitive rGO/AuNP-based electrochemical nano-biosensor for detection of E. coli and S. aureus in less than an hour

Anup Kale, Shreeram Joglekar, Preeti Joshi, Vedashree Sirdeshmukh
3 citations
AIP Advances
Advanced biosensing and bioanalysis techniques
2.42
article

Rapid and sensitive rGO/AuNP-based electrochemical nano-biosensor for detection of E. coli and S. aureus in less than an hour

Anup Kale, Shreeram Joglekar, Preeti Joshi, Vedashree Sirdeshmukh
article en
3 citations

Abstract

Improved diagnostic screening has become critical for bacterial infection identification and prevention. The sensitivity, reliability, repeatability, detection time, and specificity of a test or tool are critical for its translation to application. Electrochemical detection methods are quick and can provide point-of-care diagnosis. We report on reduced graphene oxide/gold (rGO–AuNP) nanocomposites that enabled highly sensitive and quick detection of harmful bacteria, such as E. coli and S. aureus. The technique involved employing rGO as a nano-carrier and Au as a bioactive surface to bind particular antibodies for electrochemical immunoassays. The current approach is culture-independent and does not require sample processing for bacterial detection. It is a pathogen detection technology that uses rGO–AuNP as an electrochemical transducer platform and target particular antibodies for E. coli and S. aureus to obtain improved sensitivity and speed. Differential pulse voltammetry was used to detect infections. These findings demonstrated that rGO–AuNp nanocomposites have up to three times the sensitivity of rGO and AuNP alone. Importantly, the antibody linked bioactive screen-printed electrodes remained stable for more than a month, allowing just electrochemical measurements to be performed at the time of detection. This allowed for pathogen detection in less than an hour. The limit of detection for both E. coli and S. aureus was 2 CFU/ml, making it extremely sensitive. An electrochemical sensor was showing a linear response with R2 0.98. According to the physicochemical evaluation of nanocomposites, the improved sensitivity and stability were caused by a lowered bandgap in composites and uniform distribution of AuNPs on a rGO nano-template.

AIP AdvancesVol. 15(5)
Defence Institute of Advanced Technology (IN), National Chemical Laboratory (IN), MIT World Peace University (IN), Savitribai Phule Pune University (IN)
Department of Science and Technology, Ministry of Science and Technology, India
Openalex Percentile: Top 11%
Advanced biosensing and bioanalysis techniques
2.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.