Daily and floor variations of indoor radon activity concentration in single-family houses

In this paper, the results of indoor radon level measurements in thirteen single-family houses, on different floors, are presented. The measurement was performed using the AlphaE radon metre device, and in each house, the measurements lasted six days, on average. The mean values of the radon activity concentration were in the range of 32.32-525.65 and 18.41-185.25 Bq m<sup>-3</sup> for the ground floor and first floor rooms, respectively. The results of the statistical analyses on the variation of the radon level have shown that in nine houses (69 %), there is a significant difference in radon levels, with higher levels on the ground floor compared to the first floor. The variations of the radon levels during the night and daytime hours were also statistically analysed.

Authors

Institutions

Publication Details

Journal
Isotopes in Environmental and Health Studies
Published
2025-05-29
DOI
https://doi.org/10.1080/10256016.2025.2506450
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Daily and floor variations of indoor radon activity concentration in single-family houses

Amira Kasumović, Amela Kasić, Zerina Sakić, Besima Kadrić Bajrić
Isotopes in Environmental and Health Studies
Radioactivity and Radon Measurements
article

Daily and floor variations of indoor radon activity concentration in single-family houses

Amira Kasumović, Amela Kasić, Zerina Sakić, Besima Kadrić Bajrić
article en

Abstract

In this paper, the results of indoor radon level measurements in thirteen single-family houses, on different floors, are presented. The measurement was performed using the AlphaE radon metre device, and in each house, the measurements lasted six days, on average. The mean values of the radon activity concentration were in the range of 32.32-525.65 and 18.41-185.25 Bq m<sup>-3</sup> for the ground floor and first floor rooms, respectively. The results of the statistical analyses on the variation of the radon level have shown that in nine houses (69 %), there is a significant difference in radon levels, with higher levels on the ground floor compared to the first floor. The variations of the radon levels during the night and daytime hours were also statistically analysed.

Isotopes in Environmental and Health StudiesVol. 61(5)
University of Tuzla (BA)
Openalex Percentile: Top 84%
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.