Optimization of multi-energy storage in urban building clusters

• Peak grid import dropped by 38% using hybrid battery and thermal storage • DR participation increased 45% via temperature reset and pre-cooling • Hybrid storage cut energy costs by up to 35% in optimized configurations • Budget range of $2.6M–$10.4M scaled performance without oversizing systems A data-driven optimization framework was developed to enhance energy performance in building clusters through multi-energy storage systems, combining electrical and thermal solutions. The approach used surrogate modeling, symbolic regression, and genetic programming to simulate energy consumption, integrate weather and tariff data, and refine storage strategies across varied building types. Applied to a cluster in Bismayah city, Iraq, the methodology evaluated HVAC configurations, façade designs, and thermal mass levels to tailor storage capacity recommendations. Results revealed a 38% reduction in peak grid import and a 24.6% drop in overall energy consumption when hybrid energy storage was implemented. A thermal energy storage tank capacity of 4651 kWh, coupled with a battery storage unit of 342 kWh, demonstrated a 35% decrease in energy costs. Demand response participation increased by 45% through strategic use of pre-cooling routines and temperature reset controls. TES-only configurations achieved energy usage of 16.3 kWh/m², while hybrid configurations further reduced to 8.7 kWh/m². Budget analyses showed that investments ranging from $2.6 million to $10.4 million proportionally enhanced system performance without over-sizing. The integration of Battery and Thermal Energy Storage with Phase Change Materials further supported passive thermal control, reducing HVAC reliance during peak hours.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-05-29
DOI
https://doi.org/10.1016/j.rineng.2025.105427
Citations
4
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
2.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of multi-energy storage in urban building clusters

Israa Alhani, Hassan Falah Fakhruldeen, Ibrahim Abdullah, Qusay Hassan et al.
4 citations
Results in Engineering
Advanced Battery Technologies Research
2.73
article

Optimization of multi-energy storage in urban building clusters

Israa Alhani, Hassan Falah Fakhruldeen, Ibrahim Abdullah, Qusay Hassan, Feryal Ibrahim Jabbar, Aymen Mohammed, Sameer Algburi, Ali Khudhair, Michael Ssebunya
article en
4 citations

Abstract

• Peak grid import dropped by 38% using hybrid battery and thermal storage • DR participation increased 45% via temperature reset and pre-cooling • Hybrid storage cut energy costs by up to 35% in optimized configurations • Budget range of $2.6M–$10.4M scaled performance without oversizing systems A data-driven optimization framework was developed to enhance energy performance in building clusters through multi-energy storage systems, combining electrical and thermal solutions. The approach used surrogate modeling, symbolic regression, and genetic programming to simulate energy consumption, integrate weather and tariff data, and refine storage strategies across varied building types. Applied to a cluster in Bismayah city, Iraq, the methodology evaluated HVAC configurations, façade designs, and thermal mass levels to tailor storage capacity recommendations. Results revealed a 38% reduction in peak grid import and a 24.6% drop in overall energy consumption when hybrid energy storage was implemented. A thermal energy storage tank capacity of 4651 kWh, coupled with a battery storage unit of 342 kWh, demonstrated a 35% decrease in energy costs. Demand response participation increased by 45% through strategic use of pre-cooling routines and temperature reset controls. TES-only configurations achieved energy usage of 16.3 kWh/m², while hybrid configurations further reduced to 8.7 kWh/m². Budget analyses showed that investments ranging from $2.6 million to $10.4 million proportionally enhanced system performance without over-sizing. The integration of Battery and Thermal Energy Storage with Phase Change Materials further supported passive thermal control, reducing HVAC reliance during peak hours.

Results in EngineeringVol. 26
University of Kirkuk (IQ), Al-Turath University (IQ), Imam Sadiq University (IR), Mazaya University College, Al-Farahidi University, University of Diyala (IQ)
Sustainable cities and communities
Openalex Percentile: Top 10%
Advanced Battery Technologies Research
2.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.