Numerical study of enhanced cooling in active elastocaloric regenerators with porous woven structures

Elastocaloric cooling is an emerging solid-state technology that leverages the reversible latent heat of phase transformation in superelastic shape memory alloys to achieve efficient and environmentally friendly refrigeration. The performance of the regenerator, where elastocaloric effect and heat transfer occur, critically depends on the elastocaloric material and structural design. This study employs a 1-D numerical active elastocaloric regenerator model to evaluate the cooling performance of different woven-structure regenerators. Three typical woven structures—plain weave, twilled weave, and dutch weave—are investigated across varying porosities. The results indicate that a plain weave regenerator with 30 % porosity achieves the highest performance, delivering a maximum cooling power of 485 W, a specific cooling power of 11.3 W/g, and a COP of 1.48 under a 20 K temperature span. Twilled weave regenerators exhibit comparable performance, whereas dutch weave regenerators show significantly lower cooling capabilities. Both plain and twilled weave regenerators outperform the parallel plate regenerator, increasing cooling power by a factor of 3.3, due to enhanced heat transfer and specific heat transfer area. The study highlights the potential of woven-structure regenerators for high-performance elastocaloric cooling, offering insights into optimizing regenerator design and operational parameters while emphasizing their promise for efficient and sustainable solid-state cooling systems. • Active elastocaloric regenerators based on woven structures are proposed and investigated. • A 1-D numerical model is developed to optimize the woven patterns and dimensions. • A 30 % plain weave regenerator achieves a 11.3 W/g specific cooling power with a COP of 1.48 at 20 K. • The cooling capacity of plain and twilled weave regenerators is improved significantly.

Authors

Institutions

Publication Details

Journal
Applied Energy
Published
2025-05-29
DOI
https://doi.org/10.1016/j.apenergy.2025.126180
Citations
5
Primary Topic
Advanced Materials and Mechanics
Type
article
Field-Weighted Citation Impact
3.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical study of enhanced cooling in active elastocaloric regenerators with porous woven structures

Kun Wang, Manfred Kohl, Jingyuan Xu
5 citations
Applied Energy
Advanced Materials and Mechanics
3.57
article

Numerical study of enhanced cooling in active elastocaloric regenerators with porous woven structures

Kun Wang, Manfred Kohl, Jingyuan Xu
article en
5 citations

Abstract

Elastocaloric cooling is an emerging solid-state technology that leverages the reversible latent heat of phase transformation in superelastic shape memory alloys to achieve efficient and environmentally friendly refrigeration. The performance of the regenerator, where elastocaloric effect and heat transfer occur, critically depends on the elastocaloric material and structural design. This study employs a 1-D numerical active elastocaloric regenerator model to evaluate the cooling performance of different woven-structure regenerators. Three typical woven structures—plain weave, twilled weave, and dutch weave—are investigated across varying porosities. The results indicate that a plain weave regenerator with 30 % porosity achieves the highest performance, delivering a maximum cooling power of 485 W, a specific cooling power of 11.3 W/g, and a COP of 1.48 under a 20 K temperature span. Twilled weave regenerators exhibit comparable performance, whereas dutch weave regenerators show significantly lower cooling capabilities. Both plain and twilled weave regenerators outperform the parallel plate regenerator, increasing cooling power by a factor of 3.3, due to enhanced heat transfer and specific heat transfer area. The study highlights the potential of woven-structure regenerators for high-performance elastocaloric cooling, offering insights into optimizing regenerator design and operational parameters while emphasizing their promise for efficient and sustainable solid-state cooling systems. • Active elastocaloric regenerators based on woven structures are proposed and investigated. • A 1-D numerical model is developed to optimize the woven patterns and dimensions. • A 30 % plain weave regenerator achieves a 11.3 W/g specific cooling power with a COP of 1.48 at 20 K. • The cooling capacity of plain and twilled weave regenerators is improved significantly.

Applied EnergyVol. 395
Karlsruhe Institute of Technology (DE)
Carl-Zeiss-Stiftung, Baden-Württemberg Stiftung, Klaus Tschira Stiftung, Hector Fellow Academy
Openalex Percentile: Top 7%
Advanced Materials and Mechanics
3.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.