Design and fabrication of short-period long period gratings for refractive index sensing
Fiber optic sensors offer high sensitivity and remote sensing capabilities. This study explores short-period long period gratings (SP-LPGs), fabricated via femtosecond laser, as compact and highly sensitive alternatives to conventional LPGs for refractive index (RI) sensing. Gratings with different periods were modeled and tested using a microfluidic setup. The shortest period (Λ = 13 <i>μm</i>) showed high sensitivity and RI resolution (1.1 × 10<sup>-6</sup> RIU), while the longest provided better linearity. An intermediate-period grating (Λ = 14.25 <i>μm</i>) offered optimal performance, demonstrating that period selection allows for tailoring sensitivity and linearity. These results make SP-LPGs promising for applications in medical diagnostics and environmental monitoring.
Authors
- Claudio J. Otón (ORCID: https://orcid.org/0000-0003-3831-7559)
- Fabrizio Di Pasquale (ORCID: https://orcid.org/0000-0003-0794-2626)
- Rana M. Armaghan Ayaz
- Riccardo Funari (ORCID: https://orcid.org/0000-0003-1786-3833)
Publication Details
- Journal
- Optics Express
- Published
- 2025-05-29
- DOI
- https://doi.org/10.1364/oe.566073
- Citations
- 1
- Primary Topic
- Advanced Fiber Optic Sensors
- Type
- article
- Field-Weighted Citation Impact
- 0.73
Funders
- Dipartimenti di Eccellenza
- Ministero dell'Università e della Ricerca