Speckle contrast optical spectroscopy for cuffless blood pressure estimation based on microvascular blood flow and volume oscillations

This work introduces high-speed (390 Hz) speckle contrast optical spectroscopy (SCOS) to enable simultaneous measurements of multi-anatomic site microvascular blood volume and flow oscillations. Simultaneous blood flow and volume waveforms were extracted at two wavelengths on the wrist and finger, in reflectance and transmission mode, respectively. Blood volume changes (also known as photoplethysmography, or PPG) were determined based on intensity oscillations. Blood flow information was determined based on dynamic light scattering information encoded in the 2D spatial speckle pattern after removal of stochastic and instrument noise. We extracted a wide array of temporal, shape-based, and frequency-domain features from each high-resolution waveform, as well as features that characterize the temporal relationships between these features. These features and their inter-relationships are determined by the dynamic biomechanical properties of peripheral microvasculature, including vascular compliance and resistance, which are key determinants of dynamic changes in systemic blood pressure (BP). In comparison to PPG alone, SCOS demonstrated a notable 31% improvement (p = 3.45 * 10<sup>-7</sup>) in systolic BP estimation when integrated into subject-specific machine-learning models. The resulting errors were remarkably low (systolic BP: 0.06+/- 2.88 mmHg, diastolic BP: 0.09 +/-2.14 mmHg) across a wide range of BP variations (range SBP: 89-284 mmHg). This improvement was sustained several weeks later within a re-measured cohort, indicating highly robust BP predictions. Looking ahead, high-speed SCOS holds the potential to substantially enhance the non-invasive characterization of the cardiovascular system, including continuous and non-invasive BP measurements, which are a long-sought-after goal of the biomedical community.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-05-29
DOI
https://doi.org/10.1364/boe.560022
Citations
4
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
2.70

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Speckle contrast optical spectroscopy for cuffless blood pressure estimation based on microvascular blood flow and volume oscillations

Nil Z. Gurel, Naomi M. Hamburg, Byungchan Kim, David A. Boas et al.
4 citations
Biomedical Optics Express
Non-Invasive Vital Sign Monitoring
2.70
article

Speckle contrast optical spectroscopy for cuffless blood pressure estimation based on microvascular blood flow and volume oscillations

Nil Z. Gurel, Naomi M. Hamburg, Byungchan Kim, David A. Boas, Darren Roblyer, Francesco Marsili, Edbert J. Sie, Benjamin Wilson, John P. Forman, Ariane Garrett
article en
4 citations

Abstract

This work introduces high-speed (390 Hz) speckle contrast optical spectroscopy (SCOS) to enable simultaneous measurements of multi-anatomic site microvascular blood volume and flow oscillations. Simultaneous blood flow and volume waveforms were extracted at two wavelengths on the wrist and finger, in reflectance and transmission mode, respectively. Blood volume changes (also known as photoplethysmography, or PPG) were determined based on intensity oscillations. Blood flow information was determined based on dynamic light scattering information encoded in the 2D spatial speckle pattern after removal of stochastic and instrument noise. We extracted a wide array of temporal, shape-based, and frequency-domain features from each high-resolution waveform, as well as features that characterize the temporal relationships between these features. These features and their inter-relationships are determined by the dynamic biomechanical properties of peripheral microvasculature, including vascular compliance and resistance, which are key determinants of dynamic changes in systemic blood pressure (BP). In comparison to PPG alone, SCOS demonstrated a notable 31% improvement (p = 3.45 * 10<sup>-7</sup>) in systolic BP estimation when integrated into subject-specific machine-learning models. The resulting errors were remarkably low (systolic BP: 0.06+/- 2.88 mmHg, diastolic BP: 0.09 +/-2.14 mmHg) across a wide range of BP variations (range SBP: 89-284 mmHg). This improvement was sustained several weeks later within a re-measured cohort, indicating highly robust BP predictions. Looking ahead, high-speed SCOS holds the potential to substantially enhance the non-invasive characterization of the cardiovascular system, including continuous and non-invasive BP measurements, which are a long-sought-after goal of the biomedical community.

Biomedical Optics ExpressVol. 16(8)
Boston University (US), Boston Medical Center (US), BC Platforms (Finland) (FI), Meta (United States) (US)
Meta
Openalex Percentile: Top 10%
Non-Invasive Vital Sign Monitoring
2.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.