Optimization Analysis of Overvoltage Protection Setting for Parallel Capacitor Banks

The parallel capacitor group in the substation is usually put into operation when the grid voltage drops, and is promptly disconnected when the grid voltage rises. If the disconnection is unsuccessful, there will be a delay in overvoltage protection disconnection. This article focuses on the accident of parallel capacitor banks in a 500kV substation. During the analysis of the causes, it was found that there were problems with overvoltage protection, which could not effectively protect the capacitor banks. Taking into account the effects of transformer impedance, harmonic current, and capacitor manufacturing tolerances, the reason for the high overvoltage protection setting was identified and verified through PSCAD simulation. Corresponding measures and suggestions were proposed for control strategy and overvoltage protection setting of parallel capacitor devices, providing reference for current design and operation personnel.

Authors

Institutions

Publication Details

Published
2025-03-21
DOI
https://doi.org/10.1109/sgai64825.2025.11009526
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization Analysis of Overvoltage Protection Setting for Parallel Capacitor Banks

Xiaolin Shen, X. H. Mao, Yiqi Liu, Shangan Du
Power Systems Fault Detection
article

Optimization Analysis of Overvoltage Protection Setting for Parallel Capacitor Banks

Xiaolin Shen, X. H. Mao, Yiqi Liu, Shangan Du
article en

Abstract

The parallel capacitor group in the substation is usually put into operation when the grid voltage drops, and is promptly disconnected when the grid voltage rises. If the disconnection is unsuccessful, there will be a delay in overvoltage protection disconnection. This article focuses on the accident of parallel capacitor banks in a 500kV substation. During the analysis of the causes, it was found that there were problems with overvoltage protection, which could not effectively protect the capacitor banks. Taking into account the effects of transformer impedance, harmonic current, and capacitor manufacturing tolerances, the reason for the high overvoltage protection setting was identified and verified through PSCAD simulation. Corresponding measures and suggestions were proposed for control strategy and overvoltage protection setting of parallel capacitor devices, providing reference for current design and operation personnel.

Shanghai Electric (China) (CN), Northeast Forestry University (CN)
Openalex Percentile: Top 87%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.