Study the Structural and Morphological Properties of Nano/Micro Polystyrene Treated by Argon Plasma and Apply as the Antibacterial Application

In this study, plasma parameters in DC glow discharge of argon gas were used for the pure PE film untreated and exposed of argon gas plasma (10, 20 and 25) min samples treatment. X-ray diffraction (XRD), Field Emission Scanning Electron Microscopy (FESEM) were studied for the morphological and structural films. X-ray diffraction patterns of all samples prepared were recorded. The XRD pattern shows the pure PE unexposed that the polycrystalline nature with strong peak around 2θ =21.51° with miller indices (110). After exposed with the argon plasma (10, 20 and 25) min and change the electrode distance (2.5, 3.5 and 4.5) cm, the new peak exhibited and the intensity of the all peaks increased with increasing exposed time, indicating that the orientation of the orthorhombic crystals had changed and also indicate the time exposed of argon plasma was affected. The increase in grain diameter average and particle size for pure PE film and exposed of argon gas plasma (10, 20 and 25) min with an increase in the treatment with dc glow discharge plasma was noted in the FESEM images. The contact angle of untreated pure PE and PE films after exposed of argon gas plasma (10, 20 and 25) min was measured at room temperature with water appeared of the contact angle results decrease with increasing time exposed plasma. The antibacterial activity for the pure PE film untreated and exposed of argon gas plasma (10, 20 and 25) min shows enhanced antibacterial activity against E. coli and S. aureus due to the changes in surface chemistry and physical structure, including increased hydrophilicity, surface roughness, and the generation of reactive species that can damage bacterial cells.

Authors

Institutions

Publication Details

Journal
International Journal of Computational and Experimental Science and Engineering
Published
2025-05-26
DOI
https://doi.org/10.22399/ijcesen.1530
Primary Topic
Polymer Nanocomposite Synthesis and Irradiation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study the Structural and Morphological Properties of Nano/Micro Polystyrene Treated by Argon Plasma and Apply as the Antibacterial Application

Mohaned A. Abed, Mohammed Khammass Khalaf, Ali Abdullah
International Journal of Computational and Experimental Science and Engineering
Polymer Nanocomposite Synthesis and Irradiation
article

Study the Structural and Morphological Properties of Nano/Micro Polystyrene Treated by Argon Plasma and Apply as the Antibacterial Application

Mohaned A. Abed, Mohammed Khammass Khalaf, Ali Abdullah
article en

Abstract

In this study, plasma parameters in DC glow discharge of argon gas were used for the pure PE film untreated and exposed of argon gas plasma (10, 20 and 25) min samples treatment. X-ray diffraction (XRD), Field Emission Scanning Electron Microscopy (FESEM) were studied for the morphological and structural films. X-ray diffraction patterns of all samples prepared were recorded. The XRD pattern shows the pure PE unexposed that the polycrystalline nature with strong peak around 2θ =21.51° with miller indices (110). After exposed with the argon plasma (10, 20 and 25) min and change the electrode distance (2.5, 3.5 and 4.5) cm, the new peak exhibited and the intensity of the all peaks increased with increasing exposed time, indicating that the orientation of the orthorhombic crystals had changed and also indicate the time exposed of argon plasma was affected. The increase in grain diameter average and particle size for pure PE film and exposed of argon gas plasma (10, 20 and 25) min with an increase in the treatment with dc glow discharge plasma was noted in the FESEM images. The contact angle of untreated pure PE and PE films after exposed of argon gas plasma (10, 20 and 25) min was measured at room temperature with water appeared of the contact angle results decrease with increasing time exposed plasma. The antibacterial activity for the pure PE film untreated and exposed of argon gas plasma (10, 20 and 25) min shows enhanced antibacterial activity against E. coli and S. aureus due to the changes in surface chemistry and physical structure, including increased hydrophilicity, surface roughness, and the generation of reactive species that can damage bacterial cells.

International Journal of Computational and Experimental Science and EngineeringVol. 11(2)
Thi Qar University (IQ)
Openalex Percentile: Top 90%
Polymer Nanocomposite Synthesis and Irradiation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.