Research on Fault and Protection Technology of PEDF System

DC circuit breakers are key equipment for the safe operation and protection of DC distribution networks. This paper studies the inter-pole short-circuit fault and protection of the PEDF system, and proposes a control and protection scheme based on a new all-solid-state DC circuit breaker. Firstly, a simulation model of the PEDF system is established in the PSCAD/EMTDC platform, and the fault response mechanism of the grid-connected converter when an inter-pole short-circuit fault occurs is analyzed and simulated and verified. At the same time, the topological structure and working principle of the new all-solid-state circuit breaker are briefly described. On this basis, a protection scheme for the PEDF system is designed, and relevant tests are carried out to verify the correctness of the circuit breaker design and protection scheme.

Authors

Publication Details

Published
2025-03-21
DOI
https://doi.org/10.1109/sgai64825.2025.11009357
Citations
1
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Fault and Protection Technology of PEDF System

Shibo Cong, Xingjia Wang, Peigang Ban, Yixuan Zhang et al.
1 citations
Electrical Fault Detection and Protection
0.73
article

Research on Fault and Protection Technology of PEDF System

Shibo Cong, Xingjia Wang, Peigang Ban, Yixuan Zhang, Yuan Deng, Naiyuan Fan, Xingwang Lian
article en
1 citations

Abstract

DC circuit breakers are key equipment for the safe operation and protection of DC distribution networks. This paper studies the inter-pole short-circuit fault and protection of the PEDF system, and proposes a control and protection scheme based on a new all-solid-state DC circuit breaker. Firstly, a simulation model of the PEDF system is established in the PSCAD/EMTDC platform, and the fault response mechanism of the grid-connected converter when an inter-pole short-circuit fault occurs is analyzed and simulated and verified. At the same time, the topological structure and working principle of the new all-solid-state circuit breaker are briefly described. On this basis, a protection scheme for the PEDF system is designed, and relevant tests are carried out to verify the correctness of the circuit breaker design and protection scheme.

Openalex Percentile: Top 28%
Electrical Fault Detection and Protection
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.