A Transient Synchronous Stabilization Control Strategy for Grid-Connected Dc Delivery System of Grid-Configured Offshore Wind Farms

As new energy sources are increasingly integrated into the power grid on a large scale, the proportion of gridconfigured offshore wind power DC delivery systems in the power system is increasing yearly. However, there is a lack of dynamic characteristics during its transient process. Therefore, this paper investigates the transient synchronous stability mechanism of grid-connected converters with virtual synchronous generator (VSG) control and proposes measures to enhance their transient stability. Firstly, the transient stability model of the offshore wind power DC sending system with VSG during grid fault is established to obtain the factors influencing the converter's transient stability under different faults. The control method of VSG is improved according to the system's voltage coupling effect. Finally, Matlab/Simulink is used to build a simulation model of the offshore wind power grid-connected model under the inaccessible fault, which demonstrates the effectiveness of the improved control method of the VSG and the active control strategy of the grid-side three-phase short-circuit fault.

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/cespe64643.2024.00059
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Transient Synchronous Stabilization Control Strategy for Grid-Connected Dc Delivery System of Grid-Configured Offshore Wind Farms

Ranran An, Xuefeng Qiao, Sichao Pan, Xiaobing Liang et al.
Power Systems and Renewable Energy
article

A Transient Synchronous Stabilization Control Strategy for Grid-Connected Dc Delivery System of Grid-Configured Offshore Wind Farms

Ranran An, Xuefeng Qiao, Sichao Pan, Xiaobing Liang, Baoyi Zhang, Yue Yang
article en

Abstract

As new energy sources are increasingly integrated into the power grid on a large scale, the proportion of gridconfigured offshore wind power DC delivery systems in the power system is increasing yearly. However, there is a lack of dynamic characteristics during its transient process. Therefore, this paper investigates the transient synchronous stability mechanism of grid-connected converters with virtual synchronous generator (VSG) control and proposes measures to enhance their transient stability. Firstly, the transient stability model of the offshore wind power DC sending system with VSG during grid fault is established to obtain the factors influencing the converter's transient stability under different faults. The control method of VSG is improved according to the system's voltage coupling effect. Finally, Matlab/Simulink is used to build a simulation model of the offshore wind power grid-connected model under the inaccessible fault, which demonstrates the effectiveness of the improved control method of the VSG and the active control strategy of the grid-side three-phase short-circuit fault.

Tianjin University of Technology (CN), China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 61%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.