Impact Study of 220V Induced Voltage on Insulator Resistance Measurement

When a resistance meter is used to measure insulator resistance on a complex transmission line, the adjacent operating line generates an AC induced voltage on the outage line. Under the influence of induced voltage, the resistance measuring instrument will produce a detection error when it detects a certain insulator in the insulator string. In this study, the measured resistance value is first used to simulate the three-piece insulator in the actual measurement situation, and the 220V AC voltage is connected to analyze the change of the measuring loop current of the measuring instrument under the 220V AC induction voltage, so as to calculate the resistance value measured by the resistance measuring instrument under the 220V induction voltage. The results show that when the induced voltage of 220V is present, the measured value of the resistance measuring instrument drops by 67%~72%. Finally, through the field test and in-depth statistical analysis, the simulation results of this study are consistent with the real test results. This study has a guiding significance for the accurate detection of insulators on complex lines.

Authors

Institutions

Publication Details

Published
2025-03-21
DOI
https://doi.org/10.1109/sgai64825.2025.11009881
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact Study of 220V Induced Voltage on Insulator Resistance Measurement

Wei Li, Jiamin Zhou
Electrical Fault Detection and Protection
article

Impact Study of 220V Induced Voltage on Insulator Resistance Measurement

Wei Li, Jiamin Zhou
article en

Abstract

When a resistance meter is used to measure insulator resistance on a complex transmission line, the adjacent operating line generates an AC induced voltage on the outage line. Under the influence of induced voltage, the resistance measuring instrument will produce a detection error when it detects a certain insulator in the insulator string. In this study, the measured resistance value is first used to simulate the three-piece insulator in the actual measurement situation, and the 220V AC voltage is connected to analyze the change of the measuring loop current of the measuring instrument under the 220V AC induction voltage, so as to calculate the resistance value measured by the resistance measuring instrument under the 220V induction voltage. The results show that when the induced voltage of 220V is present, the measured value of the resistance measuring instrument drops by 67%~72%. Finally, through the field test and in-depth statistical analysis, the simulation results of this study are consistent with the real test results. This study has a guiding significance for the accurate detection of insulators on complex lines.

Chinese Academy of Sciences (CN), Shanghai Institute of Microsystem and Information Technology (CN), Shanghai Maritime University (CN)
Affordable and clean energy
Openalex Percentile: Top 90%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.