Optimization of Highly Sensitive T-cell Photoacoustic Resonator for Noninvasive Blood Glucose Detection

In recent years, Photoacoustic Spectroscopy (PAS) has emerged as a powerful technique in various fields, particularly in medical diagnostics and biomedical applications. This method combines both optics and acoustics to measure the light absorption properties of materials. This paper discusses the design and performance comparison of a photoacoustic resonator (PAR) that enhances signals utilized in PAS, specifically for sensing glucose non-invasively. We designed and optimized a T-shaped PAR to improve its performance by analyzing the pressure versus frequency spectrum and observing the Q-factor. Through a step-by-step analysis, we identified the radius of both the resonance cylinder and the cavity cylinder as crucial parameters for significantly amplifying the generated ultrasonic sound signal. From our simulation data, we observed that after a certain change in the radius of the resonance cylinder, the amplitude of the pressure wave increased to approximately 7.22 times from the initial amplitude at a resonant frequency of 16.5 kHz. This analysis aims to serve as a foundation for further optimization of the resonator's performance, ultimately enhancing the detection sensitivity of non-invasive glucose monitoring devices.

Authors

Institutions

Publication Details

Published
2025-02-13
DOI
https://doi.org/10.1109/ecce64574.2025.11013286
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of Highly Sensitive T-cell Photoacoustic Resonator for Noninvasive Blood Glucose Detection

Md Rejvi Kaysir, Khan Raqib Mahmud, Mohammad Shaifur Rahman, Thasin Mohammad Zaman
Spectroscopy Techniques in Biomedical and Chemical Research
article

Optimization of Highly Sensitive T-cell Photoacoustic Resonator for Noninvasive Blood Glucose Detection

Md Rejvi Kaysir, Khan Raqib Mahmud, Mohammad Shaifur Rahman, Thasin Mohammad Zaman
article en

Abstract

In recent years, Photoacoustic Spectroscopy (PAS) has emerged as a powerful technique in various fields, particularly in medical diagnostics and biomedical applications. This method combines both optics and acoustics to measure the light absorption properties of materials. This paper discusses the design and performance comparison of a photoacoustic resonator (PAR) that enhances signals utilized in PAS, specifically for sensing glucose non-invasively. We designed and optimized a T-shaped PAR to improve its performance by analyzing the pressure versus frequency spectrum and observing the Q-factor. Through a step-by-step analysis, we identified the radius of both the resonance cylinder and the cavity cylinder as crucial parameters for significantly amplifying the generated ultrasonic sound signal. From our simulation data, we observed that after a certain change in the radius of the resonance cylinder, the amplitude of the pressure wave increased to approximately 7.22 times from the initial amplitude at a resonant frequency of 16.5 kHz. This analysis aims to serve as a foundation for further optimization of the resonator's performance, ultimately enhancing the detection sensitivity of non-invasive glucose monitoring devices.

Khulna University of Engineering and Technology (BD)
Khulna University
Zero hunger
Openalex Percentile: Top 91%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.