Study on the Effect of Transformer Oil Aging on Dielectric Loss

The open cup degradation method was used to age the transformer oil at a constant temperature of 115 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$^\circ \mathrm{C}$</tex>. The thermal aging degree of the transformer oil was analyzed by infrared spectroscopy. Based on the changes in peak position, peak intensity, and peak shape of the infrared spectrum, the changing trends of various functional groups in the preburning process of the transformer oil were determined. The preburning mechanism of the transformer oil was analyzed from a microscopic perspective. The constant voltage method was used to accelerate the insulation model of the electrically aged transformer oil. The inverse power function was used to fit the experimental data, and the voltage tolerance coefficient in the model was obtained to assess the electrical preburning of the transformer oil. The experimental results indicate that aldehydes and acid compounds are generated during the thermal preburning process of transformer oil, and the dielectric loss factor is logarithmically related to its acid value. As the transformer oil undergoes electrical preburning, the dielectric loss factor gradually raises.

Authors

Publication Details

Published
2025-03-21
DOI
https://doi.org/10.1109/sgai64825.2025.11009952
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Effect of Transformer Oil Aging on Dielectric Loss

Guobin Fu, Yongfei Ma, Xianmin Wang
Power Transformer Diagnostics and Insulation
article

Study on the Effect of Transformer Oil Aging on Dielectric Loss

Guobin Fu, Yongfei Ma, Xianmin Wang
article en

Abstract

The open cup degradation method was used to age the transformer oil at a constant temperature of 115 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$^\circ \mathrm{C}$</tex>. The thermal aging degree of the transformer oil was analyzed by infrared spectroscopy. Based on the changes in peak position, peak intensity, and peak shape of the infrared spectrum, the changing trends of various functional groups in the preburning process of the transformer oil were determined. The preburning mechanism of the transformer oil was analyzed from a microscopic perspective. The constant voltage method was used to accelerate the insulation model of the electrically aged transformer oil. The inverse power function was used to fit the experimental data, and the voltage tolerance coefficient in the model was obtained to assess the electrical preburning of the transformer oil. The experimental results indicate that aldehydes and acid compounds are generated during the thermal preburning process of transformer oil, and the dielectric loss factor is logarithmically related to its acid value. As the transformer oil undergoes electrical preburning, the dielectric loss factor gradually raises.

Openalex Percentile: Top 90%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.