Neutral line break fault identification for low-voltage power supply lines based on adaptive inspection

Aiming at the problem of low efficiency of traditional broken line fault detection methods, this paper proposes a neutral line break identification method for low-voltage power supply lines based on adaptive inspection. According to the neutral line current criterion, adaptive inspection strategy, measured data update scheme, load impedance measurement technology, and the broken line fault detection criterion that takes into account manual experience threshold and adaptive inspection data, the neutral line break fault is accurately identified. Simulation results show that the method can effectively detect the neutral line break fault, and has high reliability and engineering adaptability. Compared with the traditional method, the proposed method reduces the hardware equipment requirements, facilitates engineering implementation, and provides a new solution for the safe and stable operation of the low-voltage power supply system.

Authors

Institutions

Publication Details

Published
2025-03-21
DOI
https://doi.org/10.1109/sgai64825.2025.11009859
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Neutral line break fault identification for low-voltage power supply lines based on adaptive inspection

Shangkun Liu, Xiaoxiao Hu, Songling Ma, Qiang Chen et al.
Power Systems Fault Detection
article

Neutral line break fault identification for low-voltage power supply lines based on adaptive inspection

Shangkun Liu, Xiaoxiao Hu, Songling Ma, Qiang Chen, Zhuang Liu
article en

Abstract

Aiming at the problem of low efficiency of traditional broken line fault detection methods, this paper proposes a neutral line break identification method for low-voltage power supply lines based on adaptive inspection. According to the neutral line current criterion, adaptive inspection strategy, measured data update scheme, load impedance measurement technology, and the broken line fault detection criterion that takes into account manual experience threshold and adaptive inspection data, the neutral line break fault is accurately identified. Simulation results show that the method can effectively detect the neutral line break fault, and has high reliability and engineering adaptability. Compared with the traditional method, the proposed method reduces the hardware equipment requirements, facilitates engineering implementation, and provides a new solution for the safe and stable operation of the low-voltage power supply system.

Shanghai Electric (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 87%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.