Comparison between the performance of NIR and MIR-based PAS for non-invasive glucose detection

A significant advancement in medical diagnostics is the non-invasive measurement of glucose. The effectiveness of photoacoustic (PA) signals produced from human tissue—which can be stimulated by lasers with mid-infrared (MIR) or near-infrared (NIR) wavelengths—for the detection of glucose is investigated in this work. Our goal is to compare the sensitivity between MIR and NIR excitation for noninvasive glucose detection. We conducted MATLAB simulations and analyzed the results using a model for PA signals. The results show that the PA signal vs concentration graph has a steeper slope for MIR than for NIR, and the peak absorbance of glucose is substantially higher in the MIR region. These findings highlight MIR-based PA spectroscopy’s potential for more precise and sensitive non-invasive glucose monitoring. Sensitivity of proposed method is evaluated, displaying values of 0.2796 Pa/concentration for mid-infrared (MIR) wavelengths and 0.1697 Pa/concentration for near-infrared (NIR) wavelengths, highlighting the higher sensitivity of the MIR region for glucose concentration measurements.

Authors

Institutions

Publication Details

Published
2025-02-13
DOI
https://doi.org/10.1109/ecce64574.2025.11013879
Citations
1
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
1.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison between the performance of NIR and MIR-based PAS for non-invasive glucose detection

Tasnim Ahmed, Md Rejvi Kaysir, Khan Raqib Mahmud
1 citations
Spectroscopy Techniques in Biomedical and Chemical Research
1.63
article

Comparison between the performance of NIR and MIR-based PAS for non-invasive glucose detection

Tasnim Ahmed, Md Rejvi Kaysir, Khan Raqib Mahmud
article en
1 citations

Abstract

A significant advancement in medical diagnostics is the non-invasive measurement of glucose. The effectiveness of photoacoustic (PA) signals produced from human tissue—which can be stimulated by lasers with mid-infrared (MIR) or near-infrared (NIR) wavelengths—for the detection of glucose is investigated in this work. Our goal is to compare the sensitivity between MIR and NIR excitation for noninvasive glucose detection. We conducted MATLAB simulations and analyzed the results using a model for PA signals. The results show that the PA signal vs concentration graph has a steeper slope for MIR than for NIR, and the peak absorbance of glucose is substantially higher in the MIR region. These findings highlight MIR-based PA spectroscopy’s potential for more precise and sensitive non-invasive glucose monitoring. Sensitivity of proposed method is evaluated, displaying values of 0.2796 Pa/concentration for mid-infrared (MIR) wavelengths and 0.1697 Pa/concentration for near-infrared (NIR) wavelengths, highlighting the higher sensitivity of the MIR region for glucose concentration measurements.

Khulna University of Engineering and Technology (BD)
Zero hunger
Openalex Percentile: Top 14%
Spectroscopy Techniques in Biomedical and Chemical Research
1.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.