Improving Imaging Field of View of 3-D Transcranial Rat Brain Super-Resolution With Robotic Registered Compounding and Nonrigid Deformation Correction

Large field-of-view (FOV) brain imaging with ultrasound has become increasingly achievable with the application of 2-D probes capable of volumetric imaging. However, even in small animals the skull presents a significant barrier and conventional plane-wave transcranial imaging lacks the capability to image in some regions, resulting in incomplete super-resolved vascular reconstructions. Here a high-precision 6 degree-of-freedom robotic approach is used to optimize the transcranial transmission path and to generate composite compounded volumes that improve the field of view and imaging fill fraction. Three-dimensional transcranial simulation quantifies the effect that the skull has on US transmission, and, together with in vivo rat brain results for validation, was used to determine optimal angled transducer orientations for transcranial imaging of ±12°, laterally. Rat brain imaging with an improved FOV was accomplished by a combination of these angles with elevational translations. The 3-D super-resolution results of nine orientations were compounded together using geometric positioning data from the robot arm in combination with a nonrigid deformation correction to account for skull aberration differences. The resulting compounded result was registered against the Waxholm Space rat brain atlas, contextualizing the microvessels. As compared to the zero-angle orientation alone, the compounded result showed improvements in number of vessel-associated voxels for all examined brain regions by at least 350%. Local resolution measurements by a novel 3-D adaptation of a rolling Fourier ring correlation (FRC) approach was used to show consistent resolution measurements between orientation super-resolution results between 10 and $85~\mu $ m.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Published
2025-05-29
DOI
https://doi.org/10.1109/tuffc.2025.3574916
Citations
2
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
2.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving Imaging Field of View of 3-D Transcranial Rat Brain Super-Resolution With Robotic Registered Compounding and Nonrigid Deformation Correction

Ryan M. DeRuiter, Hatim Belgharbi, Rebecca M. Jones, Masashi Sode et al.
2 citations
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Medical Imaging Techniques and Applications
2.72
article

Improving Imaging Field of View of 3-D Transcranial Rat Brain Super-Resolution With Robotic Registered Compounding and Nonrigid Deformation Correction

Ryan M. DeRuiter, Hatim Belgharbi, Rebecca M. Jones, Masashi Sode, Gianmarco Pinton, Paul A. Dayton, Francisco Santibáñez, Hanjoo Lee
article en
2 citations

Abstract

Large field-of-view (FOV) brain imaging with ultrasound has become increasingly achievable with the application of 2-D probes capable of volumetric imaging. However, even in small animals the skull presents a significant barrier and conventional plane-wave transcranial imaging lacks the capability to image in some regions, resulting in incomplete super-resolved vascular reconstructions. Here a high-precision 6 degree-of-freedom robotic approach is used to optimize the transcranial transmission path and to generate composite compounded volumes that improve the field of view and imaging fill fraction. Three-dimensional transcranial simulation quantifies the effect that the skull has on US transmission, and, together with in vivo rat brain results for validation, was used to determine optimal angled transducer orientations for transcranial imaging of ±12°, laterally. Rat brain imaging with an improved FOV was accomplished by a combination of these angles with elevational translations. The 3-D super-resolution results of nine orientations were compounded together using geometric positioning data from the robot arm in combination with a nonrigid deformation correction to account for skull aberration differences. The resulting compounded result was registered against the Waxholm Space rat brain atlas, contextualizing the microvessels. As compared to the zero-angle orientation alone, the compounded result showed improvements in number of vessel-associated voxels for all examined brain regions by at least 350%. Local resolution measurements by a novel 3-D adaptation of a rolling Fourier ring correlation (FRC) approach was used to show consistent resolution measurements between orientation super-resolution results between 10 and $85~\mu $ m.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlVol. 72(7)
University of North Carolina at Chapel Hill (US), North Carolina State University (US), Mayo Clinic in Arizona (US)
Openalex Percentile: Top 10%
Medical Imaging Techniques and Applications
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.