Numerical study on the supersonic gas-solid two-phase injection mechanism of needle-free syringe

Supersonic gas-solid injection technology finds extensive use in drug particle delivery systems. However, the combined impact of particle diameter and mass flow rate on the delivery efficiency remain insufficiently explored. Within the Euler-Lagrange framework, this study utilizes the discrete phase method (DPM) for the numerical simulation of supersonic gas-particle flow in a needle-free injector. After validating the model's accuracy with experiment results, further investigations were conducted into the influences of particle size and mass flow rate on particle behavior and flow field properties. The results indicate that the impact of larger particles on the compressible structure is stronger, while higher mass flow rate absorbs greater energy from the gas phase, reducing the gas expansion capacity, which results in lower velocity, Mach number, and higher temperature. The jet core zone is approximately x/X = 0.3 in length. Outside core zone, the gas velocity rapidly decays and temperature rises sharply. Within the jet core zone, drug particles are accelerated and cooled, while beyond core zone, they decelerate and heat up. The strongest inter-phase interactions occur primarily in the nozzle expansion area and the jet core zone. Smaller particles reach maximum velocity upstream. This implies that in designing needle-free injectors, the nozzle-to-skin distance must match the drug particle diameter to achieve maximum penetration effectiveness. Furthermore, the particle temperature decreases with smaller sizes. As the particle diameter rises from 10 μm to 100 μm, the minimum temperatures of the particles are 145 K and 264 K, respectively, indicating the need to match the particle diameter with the minimum temperature at which the drug particles remain effective. Additionally, higher mass flow rate doses reduce injection velocity and penetration ability, necessitating the rational control of the administered dose range. These results offer significant theoretical guidance for the design and improvement of needle-free injection.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-05-29
DOI
https://doi.org/10.1371/journal.pone.0322571
Citations
2
Primary Topic
Particle Dynamics in Fluid Flows
Type
article
Field-Weighted Citation Impact
2.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical study on the supersonic gas-solid two-phase injection mechanism of needle-free syringe

Kai Qing, Hongshi Yu, Feng Zhang, Yang Xiao et al.
2 citations
PLoS ONE
Particle Dynamics in Fluid Flows
2.29
article

Numerical study on the supersonic gas-solid two-phase injection mechanism of needle-free syringe

Kai Qing, Hongshi Yu, Feng Zhang, Yang Xiao, Xiao Mo
article en
2 citations

Abstract

Supersonic gas-solid injection technology finds extensive use in drug particle delivery systems. However, the combined impact of particle diameter and mass flow rate on the delivery efficiency remain insufficiently explored. Within the Euler-Lagrange framework, this study utilizes the discrete phase method (DPM) for the numerical simulation of supersonic gas-particle flow in a needle-free injector. After validating the model's accuracy with experiment results, further investigations were conducted into the influences of particle size and mass flow rate on particle behavior and flow field properties. The results indicate that the impact of larger particles on the compressible structure is stronger, while higher mass flow rate absorbs greater energy from the gas phase, reducing the gas expansion capacity, which results in lower velocity, Mach number, and higher temperature. The jet core zone is approximately x/X = 0.3 in length. Outside core zone, the gas velocity rapidly decays and temperature rises sharply. Within the jet core zone, drug particles are accelerated and cooled, while beyond core zone, they decelerate and heat up. The strongest inter-phase interactions occur primarily in the nozzle expansion area and the jet core zone. Smaller particles reach maximum velocity upstream. This implies that in designing needle-free injectors, the nozzle-to-skin distance must match the drug particle diameter to achieve maximum penetration effectiveness. Furthermore, the particle temperature decreases with smaller sizes. As the particle diameter rises from 10 μm to 100 μm, the minimum temperatures of the particles are 145 K and 264 K, respectively, indicating the need to match the particle diameter with the minimum temperature at which the drug particles remain effective. Additionally, higher mass flow rate doses reduce injection velocity and penetration ability, necessitating the rational control of the administered dose range. These results offer significant theoretical guidance for the design and improvement of needle-free injection.

PLoS ONEVol. 20(5)
Kunming University of Science and Technology (CN), Kunming Medical University (CN), First Affiliated Hospital of Kunming Medical University (CN)
Openalex Percentile: Top 13%
Particle Dynamics in Fluid Flows
2.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.