Ballistocardiogram measurement and noise reduction by using the blind source separation

Ballistocardiogram (BCG) is the repetitive body movements related to cardiac cycle. By using non-invasive sensor embedded in a car seat, the sensor reads the vibration caused by the BCG as minute voltage at any time while driving, making it possible to measure heartbeats without being restrained and to obtain the occupant's biological information. However, BCG motion measurement while driving is difficult due to the incorporation of road noise whose magnitude is usually larger than the undisturbed BCG signal. In this study, we propose a method to extract a BCG signal from a mixture of the BCG and road noise contained in a piezoelectric film sensor using online auxiliary-function-based independent vector analysis with iterative source steering (online-AuxIVA-ISS). A device simulating BCG was placed on a seating surface, while two sensors were embedded in a seat cushion. A shaker was used to reproduce road noise disturbance on estimating the BCG. Data from the two sensors were separated into two independent signals using the online-AuxIVA-ISS. We confirmed the effectiveness of the proposed method through dynamic experiments and that the BCG-simulated signal and road noise could be separated under a moderate load on the piezoelectric film sensor.

Authors

Institutions

Publication Details

Journal
Mechanical Engineering Journal
Published
2025-01-01
DOI
https://doi.org/10.1299/mej.24-00438
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ballistocardiogram measurement and noise reduction by using the blind source separation

Mikio Toyama, Kei-ichi Kaneda, Toshihiko KOMATSUZAKI, Kouji Onoda et al.
Mechanical Engineering Journal
Non-Invasive Vital Sign Monitoring
article

Ballistocardiogram measurement and noise reduction by using the blind source separation

Mikio Toyama, Kei-ichi Kaneda, Toshihiko KOMATSUZAKI, Kouji Onoda, Nobuaki MOTOFUSA, Wataru HAYASHI
article en

Abstract

Ballistocardiogram (BCG) is the repetitive body movements related to cardiac cycle. By using non-invasive sensor embedded in a car seat, the sensor reads the vibration caused by the BCG as minute voltage at any time while driving, making it possible to measure heartbeats without being restrained and to obtain the occupant's biological information. However, BCG motion measurement while driving is difficult due to the incorporation of road noise whose magnitude is usually larger than the undisturbed BCG signal. In this study, we propose a method to extract a BCG signal from a mixture of the BCG and road noise contained in a piezoelectric film sensor using online auxiliary-function-based independent vector analysis with iterative source steering (online-AuxIVA-ISS). A device simulating BCG was placed on a seating surface, while two sensors were embedded in a seat cushion. A shaker was used to reproduce road noise disturbance on estimating the BCG. Data from the two sensors were separated into two independent signals using the online-AuxIVA-ISS. We confirmed the effectiveness of the proposed method through dynamic experiments and that the BCG-simulated signal and road noise could be separated under a moderate load on the piezoelectric film sensor.

Mechanical Engineering JournalVol. 12(3)
Kanazawa University (JP)
Affordable and clean energy
Openalex Percentile: Top 89%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.